background image

M

L1

L2

L3

R/L1

S/L2

T/L3

3-phase 200 V AC, single-phase
200 V AV or 3-phase 400 V AC

(See Note 1)

Noise Filter

Clamp core

Braking Resister
(optional)

B1

B2

U/T1

V/T2

W/T3

S1

S2

S3

S4

S5

S6

S7

MA

MB

MC

NO

SC

FS

FR

FC

RP

P1

P2

PC

AM

Common

Multi-function
photocoupler output 1

Multi-function
photocoupler ouput 2

Multi-function
photocoupler output
common

Multi-function analog output
common

Multi-function analog
output/Pulse monitor
output

1

2

3

CN2

Connector

Digital Operator

Multi-function analog voltage input

Multi-function analog current input

Analog input common

R+

R-

S+

S-

AC

(See Note 2)

}

Multi-function input 1

Multi-function input 2

Multi-function input 3

Multi-function input 4

Multi-function input 5

Multi-function input 6

Multi-function input 7

Sequence input common

Frequency reference power
supply 20mA at +12V

Frequency reference input

Frequency reference common

Pulse train input

3G3MV PFI

Multi-function contact output

NC

L1í

L2í

L3í

Note:

 Connector on CN2 wiring side:

3G3MV PCN-CN2

RS-422
communications
RS-485 selection

Pulse
generator

External frequency
adjuster
(2 k

 1/4 W min.)

3G3IVPF00C/

Standard Connections

Note 1:

Connect single-phase 200 V AC to terminals R/L1 and S/L2 of the 3G3MV-AB.

Note 2:

By using pin 2 of SW2, voltage input or current input can be selected as a frequency reference input.

Содержание SYSDRIVE 3G3MV SERIES

Страница 1: ...eu omron com 1 Apsley Way Staples Corner London NW2 7HF Fax number 020 8233 1468 Factory automation technical support 24hr technical helpsheet datasheet faxback service 020 8450 4646 General telephone...

Страница 2: ...input common R R S S AC See Note 2 Multi function input 1 Multi function input 2 Multi function input 3 Multi function input 4 Multi function input 5 Multi function input 6 Multi function input 7 Seq...

Страница 3: ...utput common Multi function analog output Output Freq Multi function analog output common Photocoupler 8mA at 24 V DC See note 2 3 20mA at 12 V DC 0 to 10 V DC 20W Response frequency 0 to 33 kHz 30 to...

Страница 4: ...Recommendations Noise Filter Specifications Y W X d H L D 8 5 Four 5 dia H1 H W1 W H 128 128 128 128 128 128 128 128 128 128 128 128 128 128 260 260 H1 118 118 118 118 118 118 118 118 118 118 118 118...

Страница 5: ...dicator is lit Note While the Inverter is in operation the parameters can be only monitored and only some parameters can be changed Any RUN command input is ignored while this indicator is lit Switche...

Страница 6: ...ogue output Carrier Frequency DC Injection Braking Current DC Injection Braking at Stop Time DC Injection Braking at Start Time Stall pevention during deceleration 0 Stall prevention enabled 1 Braking...

Страница 7: ...ence 3 9 Multi step speed reference 4 10 Inching command 12 External base block NO 13 External base block NC 17 Local Remote selection Multi function Outputs Value Function 0 Fault output 1 During RUN...

Страница 8: ...igital input has been set to 12 or 13 Forward and reverse run signal have been applied simultaneously The values in n050 through n056 for multi function inputs 1 through 7 have been duplicated check a...

Отзывы: