60
Performing an Identification Run
Section 7-3
See Fig. 45. The Enable and Stop input must be active continuously in order
to accept any run-right or run-left command. The last edge (RunR or RunL) is
valid. Fig. 47 gives an example of a possible sequence.
Fig. 47 Input and output status for edge-control
7-3
Performing an Identification Run
To get the optimum performance out of your VSD/motor combination, the VSD
must measure the electrical parameters (resistance of stator winding, etc.) of
the connected motor. See menu [229], Motor ID-Run.
It is recommended that the extended ID run be used before the motor is
installed in the application.
If this is not possible, the short ID run should be used.
!Warning
During the extended ID RUN, the motor shaft will rotate. Take safety
measures to avoid unforeseen dangerous situations.
(06-F94new_1)
INPUTS
ENABLE
STOP
RUN R
RUN L
OUTPUT
STATUS
Right rotation
Left rotation
Standstill