151
Process and Application Parameters [300]
Section 11-3
Fig. 80
MotPot function
Preset Ref 1 [362] to Preset Ref 7 [368]
Preset speeds have priority over the analogue inputs. Preset speeds are acti-
vated by the digital inputs. The digital inputs must be set to the function Pres.
Ref 1, Pres. Ref 2 or Pres. Ref 4.
Depending on the number of digital inputs used, up to 7 preset speeds can be
activated per parameter set. Using all the parameter sets, up to 28 preset
speeds are possible.
Communication information
The same settings are valid for the menus:
[363] Preset Ref 2, with default 250 rpm
[364] Preset Ref 3, with default 500 rpm
[365] Preset Ref 4, with default 750 rpm
[366] Preset Ref 5, with default 1000 rpm
[367] Preset Ref 6, with default 1250 rpm
[368] Preset Ref 7, with default 1500 rpm
Default:
Speed, 0 rpm
Dependent on:
Process Source [321] and Process Unit [322]
Speed mode
0 - max speed [343]
Torque mode
0 - max torque [351]
Other modes
Min according to menu [324] - max according to menu [325]
Modbus Instance no/
DeviceNet no:
43132–43138
Profibus slot/index
169/36–169/42
EtherCAT index (hex)
4c3c-4c42
Fieldbus format
Long
Modbus format
EInt
t
t
n
t
Motpot
UP
Motpot
DOWN
0rpm
A
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...