manualshive.com logo in svg
background image

I

M P O R T A N T

  M

E S S A G E

3    

 OMRON STI  

© 

99885-0010 Rev.A 

 1 I

MPORTANT

 M

ESSAGE

1

Please read the entire installation manual prior to installing and using this 
equipment. Only qualified personnel may install, operate or repair this 
equipment. Omron Scientific Technologies Inc. is not responsible for modified, 
altered or renovated equipment. Because the equipment has a wide range of 
applications, users must acquire the appropriate knowledge to use the 
equipment properly in their specific applications. Persons responsible for the 
application and the equipment must themselves ensure that each application is 
in compliance with all relevant requirements, standards and legislation in 
respect to configuration and safety. Only parts and accessories manufactured 
according to the specifications set by Omron Scientific Technologies Inc. may 
be used.

OMRON Scientific Technologies Inc. shall not be liable to anyone for any 
direct, indirect, special, incidental or consequential damages resulting from the 
installation, use or repair of this equipment, whether arising in tort, contract, or 
otherwise. Buyer’s sole remedy shall be the replacement, or refund of purchase 
price, and the choice of the applicable remedy shall be at the sole discretion of 
OMRON Scientific Technologies Inc.

Содержание Sti H-T40M-P

Страница 1: ...H T40M P Status Display Touchscreen Installation and Operating Manual...

Страница 2: ...ckage Contents page 6 Section 5 Specifications page 8 Section 6 Mounting Procedure page 10 Section 7 Grounding page 11 Section 8 Power Supply Wiring page 11 Section 9 Dip Switches page 12 Section 10 C...

Страница 3: ...ion and the equipment must themselves ensure that each application is in compliance with all relevant requirements standards and legislation in respect to configuration and safety Only parts and acces...

Страница 4: ...ual 3 1 GENERAL Only qualified personnel may install or operate the status display touchscreen The status display touchscreen must be installed according to the installation instructions The status di...

Страница 5: ...upplier neither guarantees that the status display touchscreen is suitable for a customer s particular application nor assumes responsibility for a customer s product design installation or operation...

Страница 6: ...y and surrounding front cover with a soft cloth and mild detergent Replacing the battery incorrectly may result in explosion Only use batteries recommend by supplier 3 7 DISMANTLING AND SCRAPPING The...

Страница 7: ...PAC KA GE C ON TEN TS 7 OMRON STI 99885 0010 Rev A Figure 4 1 Status Display Touchscreen H T40M P Figure 4 2 Installation Fasteners Figure 4 3 Power connector...

Страница 8: ...me 10 000 hours Touch screen operations 1 000 000 Active area of display W x H 58 5 x 58 5 mm Brightness cd m2 110 Processor 32 bit RISC Status LED PWR COM1 Storage temperature 10 to 60 C Relative ope...

Страница 9: ...SP ECIFICA TIONS 9 OMRON STI 99885 0010 Rev A 5 2 DESCRIPTION OF THE PARTS Figure 5 1 H T40M P Mechanical Drawing 5 3 EXTERNAL AND CUT OUT DIMENSIONS Figure 5 2 External and Cut out Dimensions...

Страница 10: ...status display touchscreen into the cut out Insert the fixtures to the holes on the unit and fasten the screws into the front of the panel Do not tighten the screws with too much or uneven force or it...

Страница 11: ...status display touchscreen Perform the following steps to wire the power connector 1 Unplug the power connector and unscrew the screws 2 Strip approximately 7 8 mm of insulation Insert the wire all t...

Страница 12: ...lt Factory Position 10 CONNECTION TO THE G9SP 10 1 Locate the included RS 232 cable with two DB9 connectors 2 Connect the HMI side of the cable to the status display touchscreen serial DB9 COM1 port 3...

Страница 13: ...g on the bottom of the main page of the Status Display Touchscreen If it is not verify the G9SP is powered up has a program running and the communication cable is correctly connected No programming in...

Страница 14: ...lar zone is in a run or stop mode Using the zone function with the G9SP requires the programming of the optional communication transmission output bits in the G9SP configurator software The status of...

Страница 15: ...Optional Communication Transmission Data Zone 4 Table 12 1 G9SP Optional Output Transmission Data Figure 12 3 G9SP Configuration Example 12 2 SAFETY INPUT STATUS This screen page will display the curr...

Страница 16: ...tail screen will display any detected errors A zero 0 indicates that there are no errors present i e normal operations If an error code is displayed click on the Code Help button for a description of...

Страница 17: ...screen will display any detected errors If all zeroes 0 are displayed no errors are present i e normal operations If an error code is displayed click on the Code Help button for a description of the...

Страница 18: ...is initiated If power loss or communication failure were to occur the machine would remain in a safe state Because there is a chance of this a redundant manual reset switch is recommended Figure 12 8...

Страница 19: ...rcuit 13 SCREEN PROPERTIES 13 From the Screen Properties screen the contrast and brightness of the screen can be adjusted Press the up or down button and the display will change immediately Press the...

Страница 20: ...nt or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information 14 Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SP...

Страница 21: ...tems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives Motion Controls Servo AC Drives Motion Controllers Encoders Temperature Pro...

Отзывы: