Overview and Specifications
Ratings/Specifications
The model names of the F3SJ-B contain the 4 digits indicating the protective height (mm).
*1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety
output at 4 Hz or less, the usable load inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including a capacitive load such as a capacitor.
*3. The Vs indicates a voltage value in your environment.
Item
Model
F3SJ-B
P25-01TS
Detection capability
Opaque objects
25 mm diameter
Beam gap
20 mm
Number of beams
8 to 102
Protective height
185 to 2,065 mm
Lens diameter
5 mm
Operating range
0.2 to 7 m
Response time
ON to OFF: 15 ms max. (Response time when used alone or in 2 or 3 connected)
OFF to ON: 70 ms max. (Response time when used alone or in 2 or 3 connected)
Startup waiting time
2 s max.
Power supply voltage (Vs)
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current consumption
Refer to "Model/Current Consumption List" on page 8.
Light source
Infrared LED (870 nm wavelength)
Effective aperture angle (EAA)
Based on IEC 61496-2.
Within ±2.5° for both emitter and receiver at an operating range of 3 meters or more.
Safety output (OSSD)
Two PNP transistor outputs, Load current: 200 mA max., Residual voltage: 2 V max.
(except for voltage drop due to cable extension), Leakage current: 1 mA max., Load
inductance: 2.2 H max. *1
Maximum capacitive load: 1 µF *2
Auxiliary output
One PNP transistor output
Load current: 100 mA max.
Residual voltage: 2 V max.(except for voltage drop due to cable extension)
Leakage current: 1 mA max.
Output operation mode
Safety output: On when receiving light
Auxiliary output: Reverse output of safety output
Input voltage
Test input is:
ON voltage: 0V to 1/2Vs, or open *3 (sink current 3mA max.)
OFF voltage: Vs-3V to Vs *3 (sink current 5mA max.)
Reset input and external device monitoring input are both:
ON voltage: Vs-3V to Vs *3 (sink current 3mA max.)
OFF voltage: 0V to 1/2Vs, or open *3 (sink current 5mA max.)
Overvoltage category
II (IEC 60664-1)
Indicator
Refer to "Internal (LED) Indicator Display Pattern" on page 4.
Mutual interference prevention function
Mutual interference prevention algorithm prevents interference in up to three sets.
Series connection function
Number of connections: Up to three sets
Total number of beams: Up to 192
Maximum connection cable length: 7 m
Test function
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-related functions
External device monitoring
Содержание Sti F3SJ-B P25-01TS Series
Страница 1: ...F3SJ B P25 01TS Series Safety Light Curtain User s Manual Cat No SCHG 734C ...
Страница 12: ...x Introduction F3SJ B User s Manual ...
Страница 82: ...68 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation ...
Страница 92: ...78 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications ...
Страница 98: ...84 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists ...