No.16S019-05
56/62
STC-SBS312POE / STC-SCS312POE / STC-SBS500POE / STC-SCS500POE
Product Specifications and User’s Guide
CounterAndTimerControl
Name
Description
CounterSelector
Selects which Counter to configure.
CounterEventSource
Select the events that will be the source to increment the Counter.
ConterDecrementEventSource
Selects the event that decrements the counter.
CounterResetSource
Selects the signals that will be the source to reset the Counter.
CounterResetActivation
Selects the Activation mode of the Counter Reset Source signal.
CounterValue
Reads or writes the current value of the selected Counter.
CounterDuration
Sets the duration (or number of events) before the CounterEnd event is generated.
CounterStatus
Returns the current status of the Counter.
CounterTriggerSource
Selects the source to start the Counter.
TimerSelector
Selects which Timer to configure.
TimerDurationRaw
It sets the duration in device-specific unit of the Timer pulse.
TimerDelayRaw
It sets the duration in device-specific unit of the delay to apply after the reception of a
trigger before start the Timer.
TimerTriggerSource
Selects the source of the trigger to start the Timer.
TimerTriggerActivation
Selects the activation mode of the trigger to start the Timer.
TimerGranularityFactor
Controls the granularity of the TimerDurationRaw and TimerDelayRaw features (in
increments of up to 30 nseconds).
TimerPeriod
Returns the period, in ns, of the selected timer.
TimerFrequency
Returns the frequrency, in Hertz, of the selected timer.
EventControl
Name
Description
PLC
Category that contains the PLC event features.
IPEngineCamHeadSerialComLog
Category that contains the IP engine to camera head serial communication log event
features.
EventSelector
Selects which Event to signal to the host application.
EventNotification
Activate or deactivate the notification to the host application of the occurrence of the
selected Event.
AnalogControl
Name
Description
GainSelector
Selects which Gain is controlled by the various Gain features.
Gain
Controls the selected gain as an absolute physical value. This is an amplification factor
applied to the video signal.
GainRaw
Controls the selected gain as an absolute physical value. This is an amplification factor
applied to the video signal.
GainAbs
Controls the selected gain as an absolute physical value. This is an amplification factor
applied to the video signal.
GainAuto
Sets the automatic gain control (AGC) mode. The exact algorithm used to implement
AGC is device-specific.
BlackLevelSelector
Selects which Black Level is controlled by the various Black Level features.
BlackLevel
Controls the black level as an absolute physical value. This represents a DC offset
applied to the video signal.
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com
Aegis
Electronic
Group,
Inc.