No.18S052-02
40/72
STC-MBS1242POE / STC-MCS1242POE
Product Specifications and User’s Guide
10.4
Exposure Time
This parameter sets variable exposure time.
The control method is selectable from
Manual exposure control, which uses preset exposure time.
Auto exposure control, which is maintain exposure time with brightness of target.
GenICam Parameters
ExposureMode
IEnumeration Type
Exposure control selection
Selection: “Off” and “Timed”
Off: Exposure time is “1 / Frame rate”
Timed: Exposure time is “Exposure Time”
ExposureTime
[ExposureTime
Selector]
IFloat Type
Exposure time (in μsecond) (*1)
Range:
212.792000 to 16,777,182.792000
Default: 107,487.792000
ExposureAuto
IEnumeration Type
Auto exposure ON / OFF selection (*2)
(*1) The approximate value of set value, sets to camera and display it.
The range of exposure time for RGB8 pixel format is 422.792000 to 16,777,182.792000
(*2) Please sets range of auto exposure control with “Exposure Auto Limit Min” and “Exposure Auto Limit Max” when
using auto exposure control.
10.5
Black Level
This parameter sets the black level (clamp level for black signal).
Sets the black level at “Black Level”.
The lower limit of signal is clamped at this setting level. The signal does not lower than this.
GenICam Parameters
BlackLevel
IFloat Type
Black Level
Range:
12bits output: 0 to 252
10bits output: 0 to 63
8bits output: 0 to 15
Default: 0