No.21S102-02
14/71
STC-LBS132POE-SWIR
Product Specifications and User’s Guide
6.4
Mechanical Specifications
Model Number
STC-LBS132POE-SWIR
Dimensions
58 (W) x 58 (H) x 85 (D) mm (*1)
Optical Filter
No Optical Filter
Optical Center Accuracy
Positional accuracy in Horizontal and Vertical directions: +/- 0.4 mm
Rotational accuracy of Horizontal and Vertical: +/- 1.5 deg.
Material
Aluminum Alloy
Lens Mount
C mount
Interface Connectors
Ethernet connector: RJ45 connector x 1
Power/IO connector: HR10A-7R-6PB (Hirose) or equivalent x 1
Camera Mounting
Eighteen M4 screw holes (Four on front, bottom, right, three on top and light plate)
Weight
Approximately 465 g
(*1) Excluding the connectors
6.5
Environmental Specifications
Model Number
STC-LBS132POE-SWIR
Operational
Temperature /
Humidity
Minimum
Environmental Temperature: 0 deg. C,
Environmental Humidity: 20 to 85 %RH (No condensation)
Maximum
Environmental Temperature: +56 deg. C, Environmental Humidity: 20 to 85 %RH (No condensation), or
Camera housing temperature (top plate) shall not 68 deg. C (*1)
Storage Temperature / Humidity
Environmental Temperature: -20 to +75 deg. C,
Environmental Humidity: 20 to 85 %RH (No condensation)
Vibration
20 Hz to 200 Hz to 20 Hz (5 min. / cycle), acceleration 10 G, XYZ 3 directions, 30 min. each
Shock
Acceleration 38 G, half amplitude 6 ms, XYZ 3 directions, 3 times each
Standard Compliancy
EMS: EN61000-6-2, EMI: EN55011
RoHS
RoHS Compliance
(*1) When the temperature sensor of camera (DeviceTemperatureSelector = Sensor) exc15 deg. C, white spots
and/or noise are increasing. Recommend using camera under less than 38 deg. C environmental temperature or camera
housing temperature (top plate) shall not 68 deg. C.
Please ensure the camera is installed with the appropriate heat dissipation. If camera has a mounted lens and a tripod with
an aluminum plate, this could decrease the camera housing temperature for heat dissipation. When the internal
temperature sensor (DeviceTemperatureSelector = Sensor) on the camera shows less than 29
deg. C, the camera housing
temperature (top plate) will be less than 68
deg. C.
Taking these steps will maintain the heat rating of the electronic components of the camera.
Upper side of camera
Measuring point