manualshive.com logo in svg
background image

Enclosed Switch

 

SHL

F-53

Lim

it 

Switch

es

Molded Terminal Models

Model Number Legend

Molded Terminal Models

Items 1 (Actuator) and 2 (Rated Current) are the same as those in 

Standard Models

.

3. Operation Indicator

None: Not provided
L:

Neon Lamp: 90 to 250 VAC

L2:

LED: 12 V

L3:

LED: 24 V

L4:

LED: 24 V

L5:

LED: 48 V

4. Location of Lead Outlet

R:

Right-hand

L:

Left-hand

D:

Underside

Use of the molded terminal model is recommended in locations subject to excessive dust, oil drips, or moisture.
All types of SHL Switches can be fabricated into a molded terminal version. In this case, the molded terminal model will have the same dimensions
an operating characteristics as the basic model from which the molded terminal model is fabricated.

Suffix by Location of Lead Outlet

Note:

Three leads (COM, NO, and NC) are provided for terminal con-
nections.

Example:

Basic type:

SHL-Q2255

Location of lead outlet:

Right-hand

When placing your order for the above Switch specify the model
number as SHL-Q2255-MR

Lead Supplies

Operation Indicator-equipped Models

UL, CSA and/or EN (IEC) approved models are available.

The molded terminal model may be equipped with an operation indicator (neon lamp or LED) upon request to facilitate maintenance and inspection.

The operation indicator is designed to illuminate when the Switch is not operating. (Because of the molded terminal model, any change to the
Switch wiring cannot be made.)

AC Operation

A neon lamp indicator is provided.
The operating voltage is 90 to 250 VAC.

Operating characteristics are the same as the basic model from
which the operation indicator equipped model is fabricated.

Dimension are the same as the standard model.

Example:

Basic type: SHL-Q2255-01MR
When placing your order for the molded terminal model with an neon
lamp operation indicator, specify the model number as SHL-Q2255-
01LMR.

Contact Circuit

1

2   3 

4

SHL-

@

55-

@@

M

@

ML

MD

MR

Location of lead outlet

Model

Right-hand

SHL-

@

-MR

Left-hand

SHL-

@

-ML

Underside

SHL-

@

-MD

Leads

Nominal cross-

sectional area

No. of conductors/

cond. dia.

Finished outside 

diameter 

Terminal 

connections

Standard length

VCTF (Vinyl cabtire 
cable)

0.75 mm

2

30/0.18 dia.

3-core 7 dia.

Black:

COM

White:

NO

Red:

NC

3 m

Matte finish

Neon lamp

Transparent terminal 
protection cover

Power supply 

Built-in switch

Load 

Neon lamp  R = 240 k

Содержание SHL -

Страница 1: ...Standard Models 1 Actuator D Plunger Q Panel mount plunger Q22 Panel mount roller plunger Q21 Panel mount crossroller plunger W Short hinge lever W1 Hinge lever W2 Short hinge roller lever W21 Hinge...

Страница 2: ...ay action hinge roller lever Agency Standard File No UL UL508 E76675 CSA CSA C22 2 No 14 LR45746 T V Rheinland EN60947 5 1 R9451332 Rated voltage Carry current Current Volt amperes Make Break Make Bre...

Страница 3: ...tate current Micro Voltage Current Load Model Rated voltage Non inductive load Inductive load Inrush current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO 125 VAC 10...

Страница 4: ...e 1 000 VAC max 300 VDC max EN60947 5 1 Pollution degree operating environment 3 EN60947 5 1 Short circuit protective device SCPD 10 A fuse type gG IEC269 Conditional short circuit current 100 A EN609...

Страница 5: ...M 1 2 NC 4 NO EN60947 5 1 Ambient temperature 5 C to 35 C Ambient humidity 40 to 50 Durability x 10 4 operations Switching current A Operating frequency 30 operations min cos 1 250 VAC Movable plunger...

Страница 6: ...tainless steel pin plunger 9 6 15 15 16 9 7 8 dia see note Note Stainless steel pin plunger Panel Mount Plunger SHL Q55 SHL Q55 01 M14 1 Two hexagon nut thickness 2 5 width 17 9 6 15 15 16 9 11 dia 4...

Страница 7: ...6 16 5 0 2 9 6 16 17 5 15 15 Hinge Lever SHL W155 SHL W155 01 Note Stainless steel lever t 1 see note 53R OP FP 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 Note Sintered stainless roller Short Hing...

Страница 8: ...One way Action Short Hinge Roller Lever SHL W355 SHL W355 01 9 5 dia 4 8 see note OP FP 35 5R Operating direction 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 90 Note Stainless sintered roller One...

Страница 9: ...and or EN IEC approved models are available The molded terminal model may be equipped with an operation indicator neon lamp or LED upon request to facilitate maintenance and inspection The operation i...

Страница 10: ...tion rubber packing will deform and thus affect the sealing capability Mounting Secure the Switch with two M4 screws and washers The tightening torque applied to each terminal must be 1 18 to 1 37 N m...

Страница 11: ...lowing diagram The above diagram is for standard conditions 5 C to 35 C 40 to 70 Since the values vary depending on the operating environ ment conditions contact your OMRON representative for further...

Страница 12: ...t of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces...

Отзывы: