
S
8
JX
39
S8JX-G
S8JX-P
Common Precautions
Input specification
100 to 240 V input
Item
Power ratings
*
1
300 W
600 W
Efficiency
5 V models
75% min.
76% min.
12 V models
77% min.
76% min.
24 V models
79% min.
78% min.
4
8
V models
78% min.
79% min.
Input
Voltage
*
2
100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC
*
8
)
Frequency
*
2
50/60 Hz (47 to 63 Hz)
Current
*
3
100 V input
4.5 A max.
8.7 A max.
200 V input
2.2 A max.
4.3 A max.
Power factor
0.9 min.
Harmonic current emissions
Conforms to EN61000-3-2
Leakage current
*
3
100 V input
0.5 mA max.
200 V input
1 mA max.
Inrush current (for a
cold start at 25
°
C)
*
3
100 V input
17.5 A max.
200 V input
35 A max.
Output
*
4
Voltage adjustment range
*
5
−
10% to 15% (with V. ADJ) (5 V, 48 V models:
±
10%)
Ripple
*
3
2% (p-p) max.
3% (p-p) max. (for only 5 V type)
*
12
Input variation influence
0.4% max.
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/
°
C max.
Startup time
1,000 ms max.
Hold time
*
3
20 ms min.
Additional
functions
Overload protection
*
6
105% to 160% of rated load current, voltage drop, intermittent, automatic reset.
Overvoltage protection
*
7
Yes
Overheat protection
Yes
Parallel operation
Yes (up to 5 Power Supplies)
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Remote sensing
Supported
Remote control
Supported
Alarm detection indication
Yes (color: red)
Alarm output
Provided, open-collector output, 30 VDC max, 50 mA max.
Other
Ambient operating temperature
Refer to the derating curve in
Engineering Data
on page 44 (with no icing or condensation).
Storage temperature
−
25 to 75
°
C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 100 mA)
100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100 mA)
500 VAC for 1 min. (between all outputs and ALM terminals; detection current: 20 mA)
Insulation resistance
100 M
Ω
min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s
2
, 3 times each in
±
X,
±
Y,
±
Z directions
*
10
Output indicator
Yes (Color: Green)
EMI
Conducted Emissions
*
3
Conforms to EN 55011 Group 1 Class B and based on FCC Class B
*
11
Radiated Emissions
Conforms to EN 55011 Group 1 Class B
*
11
EMS
Electrostatic Discharge
Conforms to EN61000-4-2
Radiated Electromagnetic Field
Conforms to EN61000-4-3
Electrical Fast Transient/Burst
Conforms to EN61000-4-4
Surge
Conforms to EN61000-4-5
Conducted Disturbance
Conforms to EN61000-4-6
Voltage Dips/Short Interruptions
Conforms to EN61000-4-11
Approved standards
*
8
UL UR: UL 508 (Recognition)
*
13
UL Listed: UL508 (Listing)
*
14
UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No.107.1, CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160) Over voltage category III,
EN 60950-1 (= VDE 0805 Teil 1)
(Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
SEMI F47-0706 (200-VAC input)
Weight
1,200 g max.
*
9
1,800 g max.
*
9
Содержание S8JX-G Series
Страница 34: ...MEMO 34...