S82K
S82K
4
Specifications Table
– continued from previous page
Item
Non–PFC models
PFC model
Single output
Dual
outputs
Single output
3 W
7.5 W
7.5 W
15 W
30 W
50 W
90 W
100 W
240 W
240 W
Output
(see
note 2)
Voltage adjust-
ment range
±
10% (V.ADJ)
Not
pos-
sible
(see
note 3)
±
10% (V.ADJ); –10% to 15% for S82K-03012/-03024/-05024
Output
(see
2)
Ripple
(see note 1)
2% (p-p) max.
(see
note 2)
Input variation
influence
0.5 % max. (at 85 to 264 VAC input, 100% load)
0.5 % max. (at 85
to 132 VAC/170
to 264 VAC input,
100% load)
0.5 %
max.
(at 85
to 132
VAC/
170 to
253
VAC in-
put,
100%
load)
0.5 % max.
(at 85 to
253 VAC in-
put, 100 %
load)
Load variation
influence
1.5% max.
(0 to 100% load)
+V:
1.5%
max.
-V: 3 %
max.
(0 to
100%
load)
1.5% max.
(0 to 100% load)
1.5% max.
(10 to 100% load)
Temperature varia-
tion influence
(see note 1)
0.05%/
°
C max.
Rise time
100 ms max. (up to 90% of output voltage at rated input
and output)
200 ms max.
300 ms
max.
1,000 ms
max.
Hold time
(see note 1)
20 ms min.
(This table continues on the next page.)
Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC).
2. The output specification is defined at the power supply output terminals.
3. The settings for the output voltage must be within the following range:
+V:
±
1% of the rated value
–V:
±
5% of the rated value
4. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will
operate at a current of 95% to 160% of the rated load current.
5. When the ambient temperature exceeds 25
°
C, the overload protection function will operate at a current of 92% to 111% of the
rated load current.
6. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON
again.