7-20
7-4 Disabling the Automatic Gain Adjustment Function
7
Adjustment Functions
Disabling the Adaptive Filter
The adaptive filter function, which performs automatic tracking in response to the load resonance,
can be disabled by setting the Adaptive Filter Selection (Pn23) to 0. If the adaptive filter is disabled
when it is correctly operating, suppressed resonance will become apparent, and noise or vibration
may occur. Therefore, before disabling the adaptive filter, perform copying function to the Notch
Filter 1 Frequency (Pn1D) of the Adaptive Filter Table Number Display (Pn2F) from the Fit Gain
Window on the front panel (refer to
Front Panel Display Example
on page 7-9) or manually set the
Notch Filter 1 Frequency (Pn1D) based on the Adaptive Filter Table Number Display (Pn2F) in the
following tables.
• Set the Notch Filter 1 Frequency (Pn1D) to 1,500 when disabling the adaptive filter using the above table.
Pn2F Notch Filter 1 Frequency (Hz)
Pn2F Notch Filter 1 Frequency (Hz)
Pn2F Notch Filter 1 Frequency (Hz)
0
(Disabled)
22
766
44
326
1
(Disabled)
23
737
45
314
2
(Disabled)
24
709
46
302
3
(Disabled)
25
682
47
290
4
(Disabled)
26
656
48
279
5
1482
27
631
49
269 (Disabled when Pn22
≥
F)
6
1426
28
607
50
258 (Disabled when Pn22
≥
F)
7
1372
29
584
51
248 (Disabled when Pn22
≥
F)
8
1319
30
562
52
239 (Disabled when Pn22
≥
F)
9
1269
31
540
53
230 (Disabled when Pn22
≥
F)
10
1221
32
520
54
221 (Disabled when Pn22
≥
E)
11
1174
33
500
55
213 (Disabled when Pn22
≥
E)
12
1130
34
481
56
205 (Disabled when Pn22
≥
E)
13
1087
35
462
57
197 (Disabled when Pn22
≥
E)
14
1045
36
445
58
189 (Disabled when Pn22
≥
E)
15
1005
37
428
59
182 (Disabled when Pn22
≥
D)
16
967
38
412
60
(Disabled)
17
930
39
396
61
(Disabled)
18
895
40
381
62
(Disabled)
19
861
41
366
63
(Disabled)
20
828
42
352
64
(Disabled)
21
796
43
339
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......