664
SIEPCYEUOQ2V01A Q2V Technical Manual
The drive detects mechanical weakening through overtorque or undertorque as specified by the conditions set in
L6-08 to L6-11 [MechFatigue Hold Off Time], and L6-56 to L6-58 [MechF Action to MechF Method]
. Set
overtorque/undertorque detection conditions in
L6-01 to L6-03 [Trq Det1 Select to Trq Det1 Time]
. The drive
disables the operation selection set in
L6-01 [Trq Det1 Select]
.
0 : Disabled
The drive does not detect mechanical weakening.
1 : Enabled
The drive detects mechanical weakening. Use parameters
L6-56 [MechF Action]
,
L6-57 [MechF AbsSpeed]
, and
L6-58 [MechF Method]
to adjust the conditions.
■
L6-09: MechFatigue Speed Detect Level
No.
(Hex.)
Name
Description
Default
(Range)
L6-09
(0469)
MechFatigue Speed Detect
Level
Sets the speed level where the drive will operate the mechanical deterioration detection function,
as a percentage of the Maximum Output Frequency.
110.0%
(-110.0 - 110.0%)
Parameters
L6-01 to L6-03 [Trq Det1 Select to Trq Det1 Time]
set the overtorque/undertorque detection
conditions.
When
L6-08 = 2, 4, 6, 8 [MechF Enable = Speed : unsigned]
, the setting value of
L6-09
is the absolute value.
When
L6-09
is set to a negative number, the drive processes this value as a positive number.
■
L6-10: MechFatigue Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
L6-10
(046A)
MechFatigue Delay Time
Sets the time for mechanical deterioration detection.
0.1 s
(0.0 - 10.0 s)
When the detection conditions set in
L6-08 [MechF Enable]
continue for the time set in
L6-10
, the drive will
detect mechanical weakening.
■
L6-11: MechFatigue Hold Off Time
No.
(Hex.)
Name
Description
Default
(Range)
L6-11
(046B)
MechFatigue Hold Off
Time
Sets the time that the drive will start mechanical deterioration detection triggered by the
cumulative operation time of the drive.
0 h
(0 - 65535 h)
When the total operation time of the drive is more than the value set in
L6-11
, the drive will detect mechanical
weakening. Use
U4-01 [Cumulative OpeTime]
to monitor the drive total operation time.
■
L6-50: Trq Det1 Type
No.
(Hex.)
Name
Description
Default
(Range)
L6-50
(04CC)
Trq Det1 Type
Sets the speed range that detects overtorque and undertorque.
0
(0, 1)
■
L6-51: Trq Det1 Action
No.
(Hex.)
Name
Description
Default
(Range)
L6-51
(04CD)
Trq Det1 Action
Sets operation of drives (operation status) after detection.
0
(0, 1)
■
L6-52: Trq Det1 Condition
No.
(Hex.)
Name
Description
Default
(Range)
L6-52
(04CE)
Trq Det1 Condition
Sets operation of drives (operation status) after detection.
0
(0, 1)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...