510
SIEPCYEUOQ2V01A Q2V Technical Manual
Related Parameters
MultSpd Ref1
H1-xx = A
MultSpd Ref2
H1-xx = B
MultSpd Ref3
H1-xx = C
MultSpd Ref4
H1-xx = D
Jog Reference
H1-xx = 6
Reference 16 (
d1-16
)
ON
ON
ON
ON
OFF
Jog Reference (
d1-17
)
-
-
-
-
ON
*1
The Jog Frequency Reference (JOG command) overrides all other frequency references.
Figure 12.49 Time Chart for Multi-step Speed Reference/JOG Reference
■
d1-01: Reference 1
No.
(Hex.)
Name
Description
Default
(Range)
d1-01
(0280)
RUN
Reference 1
Sets the frequency reference in the units from
o1-03 [FrqDisplay Unit Selection]
.
0.00 Hz
(0.00 - 590.00 Hz)
Note:
•
The upper limit value changes when the
E1-04 [Max Output Frequency]
and
d2-01 [FRef Upper Limit]
values change. Calculate the
upper limit value with this formula:
Upper limit value = (
E1-04
) × (
d2-01
) / 100
•
When
A1-02 = 6 [Control Method = PM AOLVector]
, the drive sets
o1-03 = 1 [0.01% (100%=E1-04)]
.
•
To set
d1-01
to 1-step speed parameter in a multi-step speed operation, set
b1-01 = 0 [Freq. Ref. Sel. 1 = Keypad]
.
■
d1-02: Reference 2
No.
(Hex.)
Name
Description
Default
(Range)
d1-02
(0281)
RUN
Reference 2
Sets the frequency reference in the units from
o1-03 [FrqDisplay Unit Selection]
.
0.00 Hz
(0.00 - 590.00 Hz)
Note:
•
The upper limit value changes when the
E1-04 [Max Output Frequency]
and
d2-01 [FRef Upper Limit]
values change.
•
When
A1-02 = 6 [Control Method = PM AOLVector]
, the drive sets
o1-03 = 1 [0.01% (100%=E1-04)]
.
•
To set
d1-02
to Multi-Step Speed 2, set
H3-02 and H3-10 ≠ 1 [MFAI Function Select ≠ AuxFreqRef1]
.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...