11.19 Parameters Changed by E1-03 [V/f Pattern Selection]
408
SIEPCYEUOQ2V01A Q2V Technical Manual
11.19 Parameters Changed by E1-03 [V/f Pattern Selection]
The values for parameters
A1-02 [Control Method]
and
E1-03 [V/f Pattern Selection]
change the default settings
for the parameters in these tables.
Table 11.3 Parameters Changed by E1-03 (2001 to 2021, B001 to B018, and 4001 to 4012)
No.
Unit
Setting Value
Control Method (A1-
02 Setting)
E1-03
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
OLV
(2)
OLV/
PM
(5)
AOL
V/PM
(6)
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
50.0
50.0
E1-05
V
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
50.0
50.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
2.5
3.0
-
-
E1-08
V
16.0
16.0
16.0
16.0
35.0
50.0
35.0
50.0
19.0
24.0
19.0
24.0
16.0
16.0
16.0
16.0
14.4
-
-
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.3
0.5
E1-10
V
12.0
12.0
12.0
12.0
8.0
9.0
8.0
9.0
12.0
13.0
12.0
15.0
12.0
12.0
12.0
12.0
3.0
-
-
*1
These values are the default settings for
E1-04 to E1-10
and
E3-04 to E3-10 [V/f Pattern for Motor 2]
. These settings are the same as
those for the V/f pattern when
E1-03 = 0 [CT_50-50Hzmax]
.
*2
The default setting varies depending on the setting of
E5-01 [PM Mot Code Selection]
.
*3
This is the value for 200 V class drives. Double the value for 400 V class drives.
Table 11.4 Parameters Changed by E1-03 (2030 to 2082 and 4018 to 4060)
No.
Unit
Setting Value
Control Method (A1-
02 Setting)
E1-03
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
OLV
(2)
OLV/
PM
(5)
AOL
V/PM
(6)
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
50.0
50.0
E1-05
V
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
200.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
50.0
50.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
2.5
3.0
-
-
E1-08
V
14.0
14.0
14.0
14.0
35.0
50.0
35.0
50.0
18.0
23.0
18.0
23.0
14.0
14.0
14.0
14.0
13.2
-
-
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.3
0.5
E1-10
V
7.0
7.0
7.0
7.0
6.0
7.0
6.0
7.0
9.0
11.0
9.0
13.0
7.0
7.0
7.0
7.0
2.4
-
-
*1
These values are the default settings for
E1-04 to E1-10
and
E3-04 to E3-10 [V/f Pattern for Motor 2]
. These settings are the same as
those for the V/f pattern when
E1-03 = 0 [CT_50-50Hzmax]
.
*2
The default setting varies depending on the setting of
E5-01 [PM Mot Code Selection]
.
*3
This is the value for 200 V class drives. Double the value for 400 V class drives.
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...