Promi-SD™ User Manual ver 1.0 Model: Promi-SD202-OA
www.initium.co.kr
50
If set to ‘1’, Promi-SD will accept CDC signal from other
peer (DCE-configured) Bluetooth device.
35)
ATS14
ATS14=1<cr>: Users may use DTR/DSR lines for
communications
ATS14=0<cr>: Users may use DTR/DSR lines for Loop-
back only.
Default value of ATS14 is 0.
36)
ATS15 ATS15=1<cr>:
If users set ATS15=1, users may use DTR signal to
disconnect Bluetooth connection.
If ATS15=1, and DTR signal is changed from state ON
to OFF, your connection will be disconnected.
ATS15=0<cr>: If ATS15=0, users may NOT use DTR
signal to disconnect the Bluetooth connection.
37)
ATS24
Maximum number of inquiry result (default 10)
38)
ATS29
Error Code for last occurred error.
Users can not change this value
39)
ATS31
Page Timeout (default 300)
Unit: second.
40)
ATS33
Inquiry Timeout (default 30)
Unit: second.
41)
ATS46
BD address of last connected device