Event name
Safety Process Data Communications Not Estab-
lished Error
Event code
35200000 hex
Meaning
Safety process data communications was not established with one or more safety slaves.
Source
Depends on where the Sysmac
Studio is connected and the sys-
tem configuration.
Source details
NX Unit
Detection tim-
ing
In DEBUG
mode (STOP-
PED), DEBUG
mode (RUN),
or RUN mode
Error attrib-
utes
Level
Minor fault
Recovery
Automatic re-
covery when
cause of error
is removed
Log category
System
Effects
User program
Continues.
Operation
The Unit continues to operate, but the safe states
are used for the I/O data of safety connection
where the error was detected.
System-de-
fined varia-
bles
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
The communications settings for
safety process data are not cor-
rect, the safety slave is not in the
correct status, etc.
Refer to the error for the safety
slave and correct the problem.
Refer to the errors for the safety
slaves and implement counter-
measures.
The safety slave for safety proc-
ess data communications is not
connected.
Make sure the safety slave is
connected correctly.
Make sure that all of the safety
slaves to communicate with are
connected before you change
the Safety CPU Unit to DEBUG
mode (STOPPED), DEBUG
mode (RUN), or RUN mode.
The safety slave set in the NX
Unit Mounting Setting for safety
process data communications is
disabled.
Set the disabled safety slaves in
the NX Unit Mounting Setting so
that they do not participate in
safety process data communica-
tions and then transfer the data
to the Safety CPU Unit.
Set the disabled safety slaves in
the NX Unit Mounting Setting so
that they do not participate in
safety process data communica-
tions.
Attached in-
formation
None
Precautions/
Remarks
The relevant Units will maintain the safe states for I/O data with safety connections after an error is de-
tected. However, when the cause of the error is removed, safety process data communications will re-
cover automatically.
12 Troubleshooting
12 - 33
NX-series Safety Control Unit User's Manual (Z930)
12-3 Checking for Errors with the Sysmac Studio
12
12-3-4 Error Descriptions
Содержание NX-SIH400
Страница 4: ...Introduction 2 NX series Safety Control Unit User s Manual Z930 ...
Страница 46: ...Revision History 44 NX series Safety Control Unit User s Manual Z930 ...
Страница 108: ...2 Specifications 2 42 NX series Safety Control Unit User s Manual Z930 ...
Страница 132: ...3 Installation and Wiring 3 24 NX series Safety Control Unit User s Manual Z930 ...
Страница 148: ...4 Safety Control Unit Operation 4 16 NX series Safety Control Unit User s Manual Z930 ...
Страница 216: ...5 System Configuration and Setup 5 44 NX series Safety Control Unit User s Manual Z930 ...
Страница 306: ...6 Programming 6 90 NX series Safety Control Unit User s Manual Z930 ...
Страница 378: ...7 Checking Operation and Actual Operation 7 72 NX series Safety Control Unit User s Manual Z930 ...
Страница 390: ...8 Calculating Safety Reaction Times 8 12 NX series Safety Control Unit User s Manual Z930 ...
Страница 412: ...11 Safety Data Logging 11 10 NX series Safety Control Unit User s Manual Z930 ...
Страница 504: ...12 Troubleshooting 12 92 NX series Safety Control Unit User s Manual Z930 ...
Страница 550: ...l Safety I O Terminal Settings l I O Map Settings Appendices A 38 NX series Safety Control Unit User s Manual Z930 ...
Страница 554: ...l I O Map Settings Appendices A 42 NX series Safety Control Unit User s Manual Z930 ...
Страница 558: ...l Safety I O Terminal Settings l I O Map Settings Appendices A 46 NX series Safety Control Unit User s Manual Z930 ...
Страница 564: ...l Safety I O Terminal Settings l I O Map Settings Appendices A 52 NX series Safety Control Unit User s Manual Z930 ...
Страница 623: ...I Index I 1 NX series Safety Control Unit User s Manual Z930 I ...
Страница 625: ......