P
ower Supply
The power supply to the NT2S-SF123B-EV2 is from the PLC. The figure below
shows the connection between the PLC and the unit through a cable.
PLC PORT
DB9 MALE
CONNECTOR
Connecting
Cable
DB9 FEMALE
CONNECTOR
To PLC
Programming Port
PLC
Page 8
Page 13
Page 6
Page 15
G
eneral:
The
NT2S-SF123B-EV2 is intended to be used as a low cost Operator
interface for PLCs which are rich in program memory or data memory
areas such as the Omron C Series PLCs.
The
NT2S-SF123B-EV2 has the following features:
Feature
NT2S-SF123B-EV2
Display
Backlit 2X16 LCD
LEDs
2
Keys
6
ASCII screens
32 characters
Embedded variables
16
Each key is mapped from work bits 201.00 to 201.05. Every time a key is
pressed, the corresponding bit as shown in the table below is held on while
the key is pressed. The keys also have alternate functions.
Key
Work Bit Register mode function
F1/REG
201.00
Changes register prefix
F2/DATA
201.01
Enters data entry mode
F3/DOWN
201.02
Increments register number or data
depending on mode
F4/UP
201.03
Decrements register number or data
depending on mode
F5/CLR
201.04
Clears data field to 0 / Register field to
first register value
F6/ENT
201.05
Accepts new data and sends to the PLC
K
ey definitions:
g.
Put 03032E03H in words DM0213 and DM0214. The
NT2S-SF123B-EV2
will read data in DM0003 and embed in xx.x format.
h.
Move “s “ into DM0215. This command completes the screen by
appending the “s ” to bake time.
This will put the following data in the data words below:
("b" is used for a space, i.e. 20H)
Word
ASCII
Hex
Word
ASCII
Hex
DM0200 Do
#446F
DM0208 BA
#4241
DM0201 or
#6F72
DM0209 KE
#4B45
DM0202 :b
#3A20
DM0210 TI
#5449
DM0203 CL
#434C
DM0211 ME
#4D45
DM0204 OS
#4F53
DM0212 :b
#3A20
DM0205 ED
#4544
DM0213
#0303
DM0206 bb
#2020
DM0214
#2E03
DM0207 bb
#2020
DM0215 sb
#7320
B
ar Graph:
NT2S-SF123B-EV2 uses DM0012 to DM0015 registers to hold bar graph
values to be displayed. If Offset register points to DM0200 then put
Hex value 0C0C into DM0200 onwards to display bar graph with the
value in DM0012.
Example:
Put 0C0C into DM0200, DM0201, DM0202, DM0203 and 200 into
DM0020. This will display bar graph 8 characters wide. Maximum
length is 16 characters. Each character on display can display five
vertical lines. To display full bar graph put # 80 into DM0012 and
0C0C from DM0200 to DM0207.
To display Bar Graph with value in DM0013, put 0D0D in DM0200
onwards.
R
egister mode:
In the register mode, the operator can access all the registers and bits
in the PLC.
By pressing the REG key, the operator can scroll through the register
prefixes. By using the UP / DOWN keys, the register numbers can be
accessed. Data can be changed in the registers by pressing the DATA
key. The data field will blink to indicate that the unit is ready to accept
new data. At this time, the UP / DOWN keys can be used to edit data
followed by the ENT key.
It is advisable to create a “password” screen which can block the usage
of the register mode.