  Creating Sample Screen and Setting Objects 

This section provides an example to change communication settings of a project whose 
settings are as shown below.   
Refer to “NB-series Programmable Terminals NB-Designer OPERATION MANUAL” (V106) 
for details about screen creation. 

 

1. 

Create a screen to rewrite the 
system memory with numerical 
entry objects and bit switches.     

 

2. 

Enter 3 for LW9685 to change the 
host whose PLC number is 0.   

As previously described, 3 is to 
be entered for the Ethernet host 
whose number is the lowest. 

PLC numbers 0 to 2 are reserved 
for serial communication hosts 
and not allowed to use. 

 

3. 

After entering 3 for the PLC No.0 
then confirming it, the IP address, 
port number, and node ID set to 
the host are displayed.   

 

 

 

Содержание NB-series

Страница 1: ...Programmable Terminal NB series Practices Guide New Functionalities for NB Designer V1 50 NB3Q TW01B NB5Q TW01B NB7W TW01B NB10W TW01B V462 E1 01 ...

Страница 2: ...to create NB screens It does not provide safety information Be sure to obtain the manuals for NB series Programmable Terminals read and understand the safety points and other information required for use and test sufficiently before actual use of the equipment ...

Страница 3: ...ined conditions are not warranted Reference data is intended to be used just for reference Omron does NOT guarantee that the Omron Product can work properly in the range of reference data Examples are intended for reference Omron does not warrant the conformity in usage of the examples Omron may discontinue Omron products or change specifications of them because of improvements or other reasons No...

Страница 4: ...tial of chemical contamination or electromagnetic interference facilities with vibration or impact facilities on continual operation for a long period d Applications under conditions or environment which are not described in the catalogs Omron products in the catalogs are not intended to be used in automotive applications including two wheel vehicles Please DO NOT use Omron products in automotive ...

Страница 5: ...mages arisen from or relating to Omron products Export Control Customers of Omron products shall comply with all applicable laws and regulations of other relevant countries regarding security export control in exporting Omron products and or technical documents or in providing such products and or documents to a non resident Omron products and or technical documents may not be provided to customer...

Страница 6: ... V1 50 9 3 1 Overview 9 4 How to Use New Functionalities 10 4 1 Connection Destination Setting Change 10 Related System Memory 10 Creating Sample Screen and Setting Objects 11 4 2 Project Import and Export from NB Designer Menu 13 Example Export 13 Example Import 14 4 3 Font Replacement 15 Sample Setting 15 Revision History 16 ...

Страница 7: ...rammable Terminals NB Designer OPERATION MANUAL V107 NB Q TW01B NB W TW01B NB series Programmable Terminals SETUP MANUAL V108 NB Q TW01B NB W TW01B NB series Programmable Terminals HOST CONNECTION MANUAL V109 NB Q TW01B NB W TW01B NB series Programmable Terminals STARTUP GUIDE ...

Страница 8: ...t to change without notice due to improvements Special information in this document is classified as follows Precautions for Safe Use Describes precautions on what to do and what not to do to ensure proper operation and performance Precautions for Correct Use Describes precautions on what to do and what not to do to ensure proper operation and performance Additional Information Additional informat...

Страница 9: ...B Designer V1 50 3 1 Overview This guide provides information about the following features newly added in NB Designer V1 50 1 Connection destination setting change 2 Project import and export from to NB Designer 3 Font replacement ...

Страница 10: ...f 4 is assigned the host whose PLC number is the second lowest is selected After the PLC number is set to this address the information about the target host such as current IP address is automatically set to LW9686 and higher address LW 9686 to 9689 Enter the IP address of connection destination LW9686 is the most significant byte of the IP address Ascending addresses represents the lower bytes in...

Страница 11: ...eation 1 Create a screen to rewrite the system memory with numerical entry objects and bit switches 2 Enter 3 for LW9685 to change the host whose PLC number is 0 As previously described 3 is to be entered for the Ethernet host whose number is the lowest PLC numbers 0 to 2 are reserved for serial communication hosts and not allowed to use 3 After entering 3 for the PLC No 0 then confirming it the I...

Страница 12: ...192 168 250 1 to 192 168 250 5 When you change the least significant byte of the IP address you must also change the node ID 5 Change the system memory LB9272 which updates values to ON to save the setting after editing values Reboot the NB unit to enable the saved setting ...

Страница 13: ...Designer menu allow you to export or import a project to from a pkg file Example Export Additional Information To perform a decompilation click PT Property and open the PT Extended Property tab Then check the Allow Decompilation box to enter a password 1 Start NB Designer and select File Export Project 2 Select an export destination for a pkg file 3 The export operation will succeed if the project...

Страница 14: ...ort 1 Start NB Designer and select File Import Project 2 Select a pkg file to import 3 Enter the password for decompilation 4 If the password is correct the decompilation succeeds and then a project will be unpacked ...

Страница 15: ...e missing font is replaced with the font that is on the top of the font list in the pull down menu before compilation After compilation the font is replaced with the default font 1 When you open a project including a missing font the dialog that requires confirmation for replacing the font appears 2 If you press Replace button in the dialog the dialog that allow you to select a replacement candida...

Страница 16: ...16 Revision History Revision Code Date Revision Description and Page 01 March 2020 First edition ...

Страница 17: ...843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyoto JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong R...

Отзывы: