background image

General-purpose Relay

 

MY New model

1

General-purpose Relay

MY New model

Versatile and Function-filled Miniature Power 
Relay for Sequence Control and Power 
Switching Applications

• Models with lockable test buttons now available.

• Many variations possible through a selection of operation indi-

cators (mechanical and LED indicators), lockable test button, 
built-in diode and CR (surge suppression), bifurcated contacts, 
etc.

• Arc barrier standard on 4-pole Relays.

• Dielectric strength: 2,000 VAC (coil to contact)

• Environment-friendly cadmium-free contacts.

• Safety standard approvals obtained.

• Wide range of Sockets (PY, PYF Series) and optional parts are 

available.

• Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A

• Provided with nameplate.

LR

 

Ordering Information

Relays

Standard Coil Polarity

Reverse Coil Polarity

Note: When ordering, add the rated coil voltage and “(s)” to the model number. Rated coil voltages are given in the coil ratings table.

Type

Contact form

Plug-in socket/Solder terminals

Without LED indicator

Standard with LED indicator

With LED indicator and 

lockable test button

Standard

DPDT

MY2N

MY2IN

MY2

4PDT

MY4N

MY4IN

MY4

4PDT (bifurcated)

MY4ZN

MY4ZIN

MY4Z

With built-in diode 
(DC only)

DPDT

MY2N-D2

MY2IN-D2

---

4PDT

MY4N-D2

MY4IN-D2

---

4PDT (bifurcated)

MY4ZN-D2

MY4ZIN-D2

---

With built-in CR 
(220/240 VAC, 110/120 VAC 
only)

DPDT

MY2N-CR

MY2IN-CR

---

4PDT

MY4N-CR

MY4IN-CR

---

4PDT (bifurcated)

MY4ZN-CR

MY4ZIN-CR

---

Type

Contact form

Plug-in socket/Solder terminals

With LED indicator

With LED indicator and 

lockable test button

Standard (DC only)

DPDT

MY2N1

MY2IN1

4PDT

MY4N1

MY4IN1

4PDT (bifurcated)

MY4ZN1

MY4ZIN1

With built-in diode 
(DC only)

DPDT

MY2N1-D2

MY2IN1-D2

4PDT

MY4N1-D2

MY4IN1-D2

4PDT (bifurcated)

MY4ZN1-D2

MY4ZIN1-D2

Example: MY2 6VAC (S)

Rated coil voltage

New model

Содержание MY -

Страница 1: ...everse Coil Polarity Note When ordering add the rated coil voltage and s to the model number Rated coil voltages are given in the coil ratings table Type Contact form Plug in socket Solder terminals W...

Страница 2: ...ype Poles Front Mounting Socket DIN track screwless clamp SLC Front connecting Socket DIN track screw mounting Back connecting Socket Solder Wire wrap terminals PCB terminals Socket Clip Socket Clip S...

Страница 3: ...1 mA 1 VDC 1 mA 1 VDC 100 A Item All Relays Contact resistance 100 m max Operate time 20 ms max Release time 20 ms max Max operating frequency Mechanical 18 000 operations hr Electrical 1 800 operatio...

Страница 4: ...A 250 VAC General purpose 5 A 30 VDC General purpose No of poles Coil ratings Contact ratings Operations 2 6 to 240 VAC 6 to 125 VDC 10 A 30 VDC 10 A 250 VAC 6 x 103 4 5 A 250 VAC Same polarity 5 A 30...

Страница 5: ...s 10000 5000 3000 1000 500 300 100 50 30 10 10000 5000 3000 1000 500 300 100 50 30 10 MY2 Resistive Loads MY2 Inductive Loads Endurance x10 operations 3 Switching current A 250 VAC 30 VDC 30 VDC 250 V...

Страница 6: ...Indicator Nameplate Push Button ul 94V 2 Pollution Degree 2 1 Creepage Distance 4 0 mm 3 2 mm Clearance Distance 3 0 mm 3 0 mm Contact Material Ag AgNi Au 10000 5000 3000 1000 500 300 100 50 30 10 100...

Страница 7: ...imum allowable current This approximation is not valid for loads with high inrush cur rents such as electric motors or fluorescent lamps Multiple Contact DC Switching Capacity Effect of temperature on...

Страница 8: ...odels with Test Button 0 5 6 4 MY2N 21 5 max 36 max 28 max 2 6 Eight 1 2 dia 2 2 long holes 0 5 21 5 max 36 max 6 4 MY4N 28 max 2 6 Eight 1 2 dia 2 2 long holes 36 max MY2IN 8 14 2 5 80 5 6 3 2 6 Eigh...

Страница 9: ...7 11 1 5 4 8 2 6 3 7 1 5 4 8 2 6 3 7 1 5 9 4 8 12 2 6 10 3 7 11 1 5 4 8 2 6 3 7 1 5 4 8 2 6 3 7 13 14 13 14 13 14 13 14 13 14 13 14 MY2 MY2N MY2IN AC Models MY2N MY2IN DC Models MY2N D2 MY2IN D2 DC Mo...

Страница 10: ...r the PYF08A N and PYF14A N is 55 C 4 When using the PYF08A N or PYF14A N at an operating ambient temperature exceeding 40 C reduce the current to 60 5 The MY2 S can be used at 70 C with a carry curre...

Страница 11: ...PYF08A E 31 max 23 max 72 max Two 4 2 x 5 mounting holes Eight M3 x 8 sems screws TOP VIEW Two M3 M4 or 4 5 dia holes Note Track mounting is also possible Refer to page 12 for supporting tracks PYF08...

Страница 12: ...sems screws TOP VIEW Two M3 M4 or 4 5 dia holes Note Track mounting is also possible Refer to page 12 for supporting tracks PYF14A N 4 42 3 32 2 22 1 12 8 44 7 34 6 24 5 14 41 12 31 11 21 10 11 9 A1 1...

Страница 13: ...erminal arrangement internal connections top view mounting holes PYF14 ESN PYF14 ESS 27 42 5 27 Relay Module 80 53 24 22 5 9 3 2 82 Label 75 4 45 4 45 4 45 4 1 6 3 6 4 NO NC COIL COM 27 61 82 55 29 22...

Страница 14: ...20 max PY08QN PY08QN Y1 See note 29 5 max 22 max 24 max 41 5 max 42 max Note The PY08QN Y1 includes sections indicated by dotted lines PY08 02 16 5 max 22 max 25 5 max 29 5 max Eight 1 3 dia holes PY...

Страница 15: ...per set For sockets PYF14 ESN ESS Note For total dimensions with plastic clip please refer to drawings of the sockets Model Description PYC 0 Metal spring clip Used with Relay only PYC 35 Plastic hold...

Страница 16: ...d Plate PFP M Spacer PFP S Precautions Refer to General Precautions on page 11 of the General purpose Relays and Power Relays Group Catalog X034 Connections Do not reverse polarity when connecting DC...

Отзывы: