background image

4.1 The Icons and Error Messages

Note: The irregular heartbeat symbol (

) may also be displayed 

with error messages.

4.2 Troubleshooting

4.3 Maintenance

To protect your unit from damage, please observe the following:

• Do not subject the main unit and the cuff to extreme 

temperatures, humidity, moisture or direct sunlight.

• Do not disassemble the unit.
• Do not subject the unit to strong shocks or vibrations (for 

example, dropping the unit on the floor).

• Do not use volatile liquids to clean the main unit.
• Do not wash the cuff or immerse it in water.
• Do not use petrol, thinners or similar solvents to clean the cuff.
• Do not carry out repairs of any kind yourself. If a defect occurs, 

consult your OMRON retail outlet or distributor as mentioned on 
the packaging.

• The unit should be cleaned with a soft, dry cloth.
• Use a soft, moistened cloth and soap to clean the cuff.
• Keep the unit in its storage case when not in use.
• Fold the cuff into the storage case.

Do not store the unit in the following situations:

• If the unit is wet.
• Locations exposed to extreme temperatures, humidity, direct 

sunlight, dust or corrosive vapours.

• Locations exposed to vibrations, shocks or where it will be at an 

angle.

Calibration and Service

• The accuracy of this blood pressure monitor has been carefully 

tested and is designed for a long service life.

• It is generally recommended to have the unit inspected every 

two years to ensure correct functioning and accuracy. Please 
consult your authorised OMRON dealer or the OMRON 
Customer Service at the address given on the packaging or 
attached literature. 

Note: Subject to technical modification without prior notice. 

• This device fulfils the provisions of EC directive 93/42/EEC 

(Medical Device Directive).

• This blood pressure monitor is designed according to the European 

Standard EN1060, Non-invasive sphygmomanometers Part 1: 
General Requirements and Part 3: Supplementary requirements 
for electromechanical blood pressure measuring systems.

• This OMRON product is produced under the strict quality system of 

OMRON HEALTHCARE Co. Ltd., Japan. The Core component for 
OMRON blood pressure monitors, which is the Pressure Sensor, is 
produced in Japan.

Thank you for buying an OMRON product. This product is 
constructed of high quality materials and great care has been taken 
in its manufacturing. It is designed to give you every satisfaction, 
provided that it is properly operated and maintained as described in 
the instruction manual.
This product is guaranteed by OMRON for a period of 2 years after 
the date of purchase. The proper construction, workmanship and 
materials of this product is guaranteed by OMRON. During this 
period of guarantee OMRON will, without charge for labour or parts, 
repair or replace the defect product or any defective parts.

The guarantee does not cover any of the following:

a. Transport costs and risks of transport.
b. Costs for repairs and / or defects resulting from repairs done by 

unauthorised persons.

c. Periodic check-ups and maintenance.
d. Failure or wear of attachments other than the main device itself, 

unless explicitly guaranteed above.

e. Costs arising due to non-acceptance of a claim (those will be 

charged for).

f. Damages of any kind including personal caused accidentally or 

from misuse.

g. Calibration service is not included within the guarantee.

Should guarantee service be required please apply to the dealer 
whom the product was purchased from or an authorised OMRON 
distributor. For the address refer to the product packaging / literature 
or to your specialised retailer.

If you have difficulties in finding OMRON customer services, contact 
us for information.

www.omron-healthcare.com

Repair or replacement under the guarantee does not give rise to any 
extension or renewal of the guarantee period.
The guarantee will be granted only if the complete product is 
returned together with the original invoice / cash ticket issued to the 
consumer by the retailer.

What is Blood Pressure?

Blood pressure is a measure of the force of blood flowing against the 
walls of the arteries. Arterial blood pressure is constantly changing 
during the course of the heart’s cycle. 
The highest pressure in the cycle is called the 

Systolic Blood 

Pressure

; the lowest is the 

Diastolic Blood Pressure

. Both 

pressures, the 

Systolic

 and 

Diastolic

, are necessary to enable a 

physician to evaluate the status of a patient’s blood pressure.

What is Arrhythmia?

Arrhythmia is a condition where the heartbeat rhythm is abnormal 
due to flaws in the bio-electrical system that drives the heartbeat. 
Typical symptoms are skipped heartbeats, premature contraction, 
an abnormally rapid (tachycardia) or slow (bradycardia) pulse.

Why is it a Good Thing to measure Blood Pressure 
at Home?

Many factors such as physical 
activity, anxiety, or the time of day, 
can influence your blood pressure. 
A single measurement may not be 
sufficient for an accurate diagnosis. 
Thus it is best to try and measure 
your blood pressure at the same 
time each day, to get an accurate indication of any changes in blood 
pressure. Blood pressure is typically low in the morning and 
increases from afternoon to evening. It is lower in the summer and 
higher in the winter.

How are hypertension and irregular heartbeat 
linked to stroke?

Hypertension (high blood pressure) and atrial fibrillation are two 
major risk factors of stroke. 
Irregular heartbeat is a potential indicator of atrial fibrillation. 
Omron Blood Pressure monitors can help to detect hypertension 
and irregular heartbeat*.
If either or both are indicated by the device, we recommend to 
consult your doctor.
NOTE: Diagnosis can only be made by a doctor
* Irregular heartbeat detection is available on most Omron blood 

pressure monitors.

Made in Vietnam

Error Display

Cause

Remedy

Irregular heartbeats 
are detected.

Remove the wrist cuff. Wait 
2 - 3 minutes and then take 
another measurement.
Repeat the steps in section 
3.3. If this error continues to 
appear, contact your doctor.

Blink

The batteries are 
low.

You should replace them with 
new ones ahead of time.
Refer to section 2.1.

Lit

The batteries are 
exhausted. 

You should replace them with 
new ones at once.
Refer to section 2.1.

Wrist cuff not 
applied correctly.

Apply the wrist cuff correctly.
Refer to section 3.1.

Movement during 
measurement.

Repeat Measurement while 
remaining still and refraining 
from talking during the 
measurement.
Refer to section 3.3.

Wrist cuff not 
applied correctly, or 
movement during 
measurement.

Apply the wrist cuff correctly 
and repeat measurement 
while remaining still and 
refraining from talking during 
the measurement.
Refer to section 3.1 and 3.3.

Arm position 
changed during 
measurement.

Remain still until the 
measurement is complete.
Refer to section 3.3.

Device error.

Contact your OMRON retail 
outlet or distributor.

Problem

Cause

Remedy

The reading is 
extremely low 
(or high).

The wrist cuff is not 
at heart level.

Measure while in the 
correct posture.
Refer to section 3.2 and 
3.3.

The cuff is not 
wrapped snugly 
around the wrist.

Wrap the cuff correctly.
Refer to section 3.1.

The arms and 
shoulders are 
tense.

Relax and try taking the 
measurement again.
Refer to section 3.3.

Movement or 
talking during 
measurement.

Remain still and do not 
talk during Measurement.
Refer to section 3.3.

Wrist cuff pressure 
does not rise.

Air is leaking from 
the wrist cuff.

Consult your OMRON 
retail outlet or distributor.

Wrist cuff deflates 
too soon.

The wrist cuff is 
loose.

Apply the cuff correctly so 
that it is firmly wrapped 
around the wrist. Refer to 
section 3.1.

The blood pressure is different 
each time. The reading is 
extremely low (or high).

Blood pressure readings 
constantly vary with time 
of day and how relaxed 
you are. Take several 
deep breaths and try to 
remain relaxed before 
taking a measurement.

The unit loses 
power during 
measurement.

The batteries are 
exhausted.

Replace the batteries with 
new ones.
Refer to section 2.1.

Nothing happens 
when you press 
the buttons.

The batteries have 
been inserted 
incorrectly.

Insert the batteries with 
the correct (+/-) polarity.
Refer to section 2.1.

Other problems.

• Press the START/STOP button and repeat 

measurement.

• If the problem continues, try replacing the 

batteries with new ones.

If this still does not solve the problem, contact 
your OMRON retail outlet or distributor.

4 Troubleshooting and Maintenance

Product description

OMRON Wrist Blood Pressure Monitor

Model

MIT Precision 5 (HEM-6150-E)

Display

LCD Digital Display

Measurement method

Oscillometric method

Measurement range

Pressure: 0 to 299 mmHg 
Pulse: 40 to 180 beats/min.

Accuracy

Pressure: ±3 mmHg 
Pulse: ±5% of display reading

Inflation

Automatic inflation by pump

Deflation

Automatic rapid deflation

Memory

90 Measurements

Power source

2 “AAA” batteries 1.5V 

Battery life

Approx. 300 measurements with new 
alkaline batteries at a room temperature of 
23°C

Applied part

= Type BF

Protection against 
electric shock

Internally powered ME equipment

Operating temperature/ 
humidity

+10 to +40°C / Maximum: 15 to 85% RH

Storage temperature/ 
humidity/air pressure

-20 to +60°C / Maximum: 10 to 95% RH / 
700 to 1060hPa

Console weight

Approximately 123g without batteries

Outer dimensions

Approximately 86.7 (w) mm x 67 (h) mm x 
28 (d) mm (without the wrist cuff)

Measurable 
circumference

Approximately 13.5 to 21.5 cm

Cuff material

Nylon and polyester

Package content

Main unit, storage case, battery set, 
instruction manual

5 Technical Data

Important information regarding Electro Magnetic 
Compatibility (EMC)

With the increased number of electronic devices such as PC’s and 
mobile (cellular) telephones, medical devices in use may be 
susceptible to electromagnetic interference from other devices. 
Electromagnetic interference may result in incorrect operation of 
the medical device and create a potentially unsafe situation.
Medical devices should also not interfere with other devices.

In order to regulate the requirements for EMC (Electro Magnetic 
Compatibility) with the aim to prevent unsafe product situations, the 
EN60601-1-2:2007 standard has been implemented. This standard 
defines the levels of immunity to electromagnetic interferences as 
well as maximum levels of electromagnetic emissions for medical 
devices.

This medical device manufactured by OMRON HEALTHCARE 
conforms to this EN60601-1-2:2007 standard for both immunity and 
emissions.
Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which 

generate strong electrical or electromagnetic fields, near the 
medical device. This may result in incorrect operation of the unit 
and create a potentially unsafe situation. Recommendation is to 
keep a minimum distance of 7 m. Verify correct operation of the 
device in case the distance is shorter.

Further documentation in accordance with EN60601-1-2:2007 is 
available at OMRON HEALTHCARE EUROPE at the address 
mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.

Correct Disposal of This Product 
(Waste Electrical & Electronic Equipment)

This marking shown on the product or its 
literature, indicates that it should not be 
disposed of, with other household wastes at the 
end of its working life. 
To prevent possible harm to the environment or human health from 
uncontrolled waste disposal, please separate this product from 
other types of wastes and recycle it responsibly to promote the 
sustainable reuse of material resources.

Household users should contact either the retailer where they 
purchased this product, or their local government office, for details 
of where and how they can return this item for environmentally safe 
recycling.
Business users should contact their supplier and check the terms 
and conditions of the purchase contract. This product should not be 
mixed with other commercial wastes for disposal. 

6 Warranty

Manufacturer

OMRON HEALTHCARE Co., Ltd.

53, Kunotsubo, Terado-cho, Muko, KYOTO, 
617-0002 JAPAN

EU-representative

OMRON HEALTHCARE EUROPE B.V.

Scorpius 33, 2132 LR Hoofddorp, 
THE NETHERLANDS
www.omron-healthcare.com

Production facility

OMRON HEALTHCARE MANUFACTURING 
VIETNAM CO., LTD.

No.28 VSIP II, Street 2, Vietnam-Singapore 
Industrial Park II,
Binh Duong Industry-Services-Urban Complex,
Hoa Phu Ward, Thu Dau Mot City,
Binh Duong Province,
Vietnam

Subsidiaries

OMRON HEALTHCARE UK LTD.

Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, 
UK
www.omron-healthcare.co.uk

OMRON MEDIZINTECHNIK 
HANDELSGESELLSCHAFT mbH

Gottlieb-Daimler-Strasse 10, 68165 Mannheim, 
GERMANY
www.omron-healthcare.de

OMRON SANTÉ FRANCE SAS

14, rue de Lisbonne, 93561 Rosny-sous-Bois 
Cedex, FRANCE
www.omron-healthcare.fr

7 Some Useful Information about Blood Pressure

Example: fluctuation within a day (male, 35 years old)

mmHg

200

150

100

50

6

12

18

24

Upper curve: systolic blood pressure
Lower curve: diastolic blood pressure

Time of day

Отзывы: