background image

11

BATTERY

•  

Do not throw the batteries into a fire.

 The batteries may explode.

•  

Dispose of the unit, batteries, and components according to applicable legal 

regulations.

 Unlawful disposal may cause environmental pollution.

•  

Do not mix alkaline and manganese batteries

 as this will shorten the battery life.

•  During therapy, do not remove the battery cover and do not touch the battery terminals.

•  Do not use batteries after their expiration date.

PADS

  The size, shape and type of pads may affect the safety and effectiveness

 of electrical 

stimulation.

•  

The electrical performance characteristics of pads may affect the safety and 

effectiveness

 of electrical stimulation.

•  

Using pads that are too small or incorrectly applied

, could result in discomfort or 

skin burns.

•  Detach the pads before replacing the batteries.

General Precautions

•  

The long-term effects of electrical stimulation are unknown. 

•  

Apply stimulation to only normal, intact, clean, dry and healthy skin.

•  

TENS is not effective in treating the original source or cause of the pain, including headache. 

•  

TENS is not a substitute for pain medications and other pain management therapies. 

•  

TENS devices do not cure disease or injuries. 

•  

TENS is a symptomatic treatment and, as such, suppresses the sensation of pain that 

would otherwise serve as a protective mechanism.

•  Effectiveness is highly dependent upon patient selection by a practitioner qualified in the 

management of pain patients.

•  

You may experience skin irritation or hypersensitivity 

due to the electrical stimulation 

or electrical conductive medium (gel).

•  

Keep unit away from young children.

 The unit contains small pieces that may be swallowed. 

Immediately contact your physician.

•  

Ensure that this device has acclimated to room temperature before using. Using this 

device after an extreme temperature change could lead to an improper operation. OMRON 

recommends waiting for approximately 2 hours for the device to warm up or cool down 

when the device is used in an environment within the temperature specified as operating 

conditions after it is stored either at the maximum or at the minimum storage temperature. 

For operating, storage and transport conditions, refer to page 34.

•  

The clip may fall off if attached to soft or thin clothing.

4. IMPORTANT SAFETY PRECAUTIONS AND WARNINGS

Содержание Max Power Relief PM500

Страница 1: ...INSTRUCTION MANUAL TENS Therapy Pain Relief Max Power Relief PM500 Pads are for Single Patient Use Only ENGLISH...

Страница 2: ...WARNINGS 6 5 HOW MAX POWER RELIEF WORKS 13 6 KNOW YOUR UNIT 14 7 ASSEMBLY STEPS 16 8 GET STARTED WITH YOUR THERAPY 19 9 HOW TO CONTROL AND REDUCE YOUR PAIN 26 10 CLEANING AND STORAGE 28 11 TROUBLESHOO...

Страница 3: ...erve stimulation to the surface of the skin near the site of the pain The Max Power Relief uses comfortable self adhesive Long Life Pads that can be used up to 150 times TENS is a safe and drug free p...

Страница 4: ...shoulder or foot due to strain from exercise or normal household and work activities When used for the symptomatic relief and management of chronic intractable pain and relief of pain associated with...

Страница 5: ...on visit OmronHealthcare com symbols glossary Contraindication Do not use this device if you have a cardiac pacemaker implanted defibrillator or other implanted metallic or electronic device Such use...

Страница 6: ...ultaneous connection of a patient to high frequency surgical ME equipment may result in burns at the site of the stimulator electrodes and possible damage to the stimulator For Hospitals and Clinics O...

Страница 7: ...cture If you have suspected or diagnosed heart disease you should follow precautions recommended by your physician If you have suspected or diagnosed epilepsy you should follow precautions recommended...

Страница 8: ...normal sensation DO NOT USE THIS UNIT DURING THESE ACTIVITIES When in the bath or shower While sleeping While driving operating machinery or during any activity in which electrical stimulation can put...

Страница 9: ...mulation near your eyes and to your head and face CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or cause damage...

Страница 10: ...erly or you feel discomfort immediately stop using it Do not use for any other purpose except for what it is intended Do not place in a room with high humidity such as a bathroom This will damage the...

Страница 11: ...adache TENS is not a substitute for pain medications and other pain management therapies TENS devices do not cure disease or injuries TENS is a symptomatic treatment and as such suppresses the sensati...

Страница 12: ...eactions Do not use to treat one region for extended periods of time more than 30 minutes a session up to three times day or muscles in that region may become exhausted and sore 4 IMPORTANT SAFETY PRE...

Страница 13: ...s move through the skin to nearby nerves to block or shut out the pain message from ever reaching the brain from the source of the pain 2 Gentle electrical pulses increase the production of the body s...

Страница 14: ...NIT PACKAGE CONTENTS Main Unit Electrode Cords Batteries 2 AAA size LR03 batteries Belt Clip Soft Pouch Pad Holder 1 standard 2 LONG LIFE PADS 1 standard pair Instruction Manual Quick Start Guide Pad...

Страница 15: ...ry icon displays to remind you when to replace the batteries 7 Pad icon displays if pad falls off BUTTONS AND THEIR FUNCTIONS Cord Intensity Level Minutes Remaining Pad Icon If the pad dislodges the p...

Страница 16: ...nection is not broken 4 The unit is intact and working 5 There is no battery leakage STEP 1 INSERT BATTERIES 1 Remove the battery cover on the back using a coin Battery Cover 2 Insert batteries Make s...

Страница 17: ...ITHER ELECTRODE CORD TO EACH OF THE PADS For the first time take the pads out of the sealed package CAUTION Do NOT turn unit on until pads are on your skin Therapy won t work with just one pad You MUS...

Страница 18: ...Discard the plastic film backing as well as the clear packaging STORING PADS ON PAD HOLDER Remove plastic film and put sticky side of pads on either side of the pad holder STEP 5 ATTACH THE UNIT TO TH...

Страница 19: ...rk with just one pad You MUST USE TWO PADS at the same time Do not overlap pads or put pads on top of each other Do not add spray lotions or creams to skin or pads Do not share pads with another perso...

Страница 20: ...LOWER BACK Attach one pad below and above the region in pain both on same side LEG HIP THIGH Attach pads on each side of the area with pain ARM Attach pads on each side of the region where you feel pa...

Страница 21: ...Attach pads on the left for pain on the outside of your ankle foot Attach the pads on the right for pain on the inside of your ankle foot WARNING Do not apply the pads on the bottom of both feet at th...

Страница 22: ...SHOULDER Attach one pad on the front and on the back of your shoulder WARNING Do not apply the pads on both sides of the chest cavity simultaneously lateral or front and back or across your chest beca...

Страница 23: ...ulder How to switch modes The unit automatically defaults to the last mode selected Each time you push the mode button it switches to the next mode at the lowest intensity You can only use ONE MODE at...

Страница 24: ...e sensations Series of low to medium tapping and rubbing sensations Series of low rate tapping pulsing sensations Arm Lower Back Leg Foot Therapies designed for Joint Shoulder Tap Knead Rub What does...

Страница 25: ...If the stimulation sensation becomes weaker or disappears increase the intensity until it is restored But if the sensation is at all uncomfortable press the down arrow to decrease the intensity Press...

Страница 26: ...f pain has reduced or stopped Press the On button to continue therapy for another 15 minute session 1 session Max minutes session Max times day 15 minute 30 minutes 3 times per day automatic shut off...

Страница 27: ...pain you may have pain in more than one area and for longer than 6 months Chronic pain may be compounded by other issues that this unit cannot address Remember this unit does not cure your pain or the...

Страница 28: ...o 150 uses Do not wash the pads too long or too frequently 4 Dry the non sticky surface of the pads and let the adhesive surface air dry completely Do not wipe with a tissue paper or cloth 5 Pads are...

Страница 29: ...belt clip on Store the pads with the electrode cords on the pad holder and put into the pouch Do not keep in areas subject to direct sunlight high or low temperatures humid areas near a fire vibratio...

Страница 30: ...ntensity setting getting weak Press the up button Is the gel damaged Replace pad Are the batteries weak Replace both AAA batteries Is the intensity 1 Press the up button The skin turns red or the skin...

Страница 31: ...too long and or too frequently Leave the pad in freezer for overnight Were the pads stored under high temperature high humidity or direct sunshine Replace both pads Pad icon is displayed Only one pad...

Страница 32: ...and the return shipping and handling fee that may apply Enclose the proof of purchase Include a letter with your name address phone number and description of the specific problem Pack the product car...

Страница 33: ...nty provides you with specific legal rights and you may have other rights that vary by jurisdiction FOR CUSTOMER SERVICE Visit our web site at OmronHealthcare com Call toll free 1 800 634 4350 12 LIMI...

Страница 34: ...1060 hPa Weight Approx 3 5 oz 100 g incl batteries Outer Dimension Approx 2 W 4 4 H 1 D 52 mm 112 mm 25 mm Classification of ME equipment Internally powered IP classification IP 22 Operation Mode Cont...

Страница 35: ...35 Optional Accessories PMLLPAD L 3 x4 5 75 mm 114 mm PMLLPAD 2 5 x4 63 mm 102 mm To order OmronHealthcare com 13 SPECIFICATIONS...

Страница 36: ...stalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Страница 37: ...of IEC60601 1 2 2014 Important information regarding Electromagnetic Compatibility EMC PM500 conforms to IEC60601 1 2 2014 Electromagnetic Compatibility EMC standard Further documentation in accordan...

Страница 38: ...LTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Distributed by OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A OmronHealthcare com 2019 OMRON HEALTHCARE INC Made...

Страница 39: ...care helps you make positive lifestyle changes with innovative medical solutions that you can use safely and accurately at home OmronHealthcare com For questions 1 800 634 4350 Get general pain info O...

Отзывы: