ZX Series (ZX-L-N)
Smart Sensors (Laser Type)
17
Laser Safety
The ZX-LD-Series
Sensor Heads are FDA Class II and EN Class 2 Laser Products. The ZX-LT-Series
Sensor Heads are FDA Class II and EN
Class 1 Laser Products. The ZX Series is meant to be built into final system equipment. Pay special attention to the following precautions for the
safe use of the product:
Note: Europe: Class 1 and Class 2 of EN60825-1: 1994 = IEC825-1: 1993
U.S.A.: Class I and Class II of FDA (21 CFR1040.10)
1. Use this product as specified in this instruction manual. Otherwise, you may be exposed to hazardous laser radiation.
2. The ZX-series Smart Sensors radiate laser beams in the visible light range. Do not expose your eyes directly to the laser radiation. Ensure
that the laser beam path is terminated during use. If a mirror or shiny surface is positioned in the laser beam path, ensure that the reflected
beam path is also terminated. If the Unit must be used without terminating the laser beam path, position the laser beam path so that it is not
at eye level.
3. To avoid exposure to hazardous laser radiation, do not displace nor remove the protective housing during operation, maintenance, and any
other servicing.
4. The user should return the product to OMRON for all repair and servicing.
5. As for other countries, observe the regulations and standards specified by each country.
Requirements from Regulations and Standards
EN60825-1 “Safety of Laser Products, Equipment Classification, Requirements and User’s
Guide”
●
Summary of Manufacturer’s Requirements
*With respect to the requirements of remote interlock connector, key control, emission warning and attenuator, Class 3B laser products not
exceeding five times the AEL of Class 2 in the wavelength range of 400 nm to 700 nm are to be treated as Class 3A laser products.
Note 1. This table is intended to provide a convenient summary of requirements. See text of this standard for complete requirements.
Requirements;
Sub-clause
Classification
Class 1
Class 2
Class 3A
Class 3B*
Class 4
Description of hazard
class
Safe under reason-
ably foreseeable con-
ditions
Low power; eye pro-
tection normally af-
forded by aversion
responses
Same as Class 2. Di-
rect intrabeam view-
ing with optical aids
may be hazardous
Direct intrabeam view-
ing may be hazardous
High power; diffused
reflection may be haz-
ardous
Protective housing
Required for each laser product; limits access necessary for performance of functions of the products
Safety interlock in pro-
tective housing
Designed to prevent removal of the panel until accessible emission values are below the AEL (see note 2) for the class
assigned
Remote control
Not required
Permits easy addition of external interlock in la-
ser installation
Key control
Not required
Laser inoperative when key is removed
Emission warning de-
vice
Not required
Gives audible or visible warning when laser is
switched on or if capacitor bank of pulsed laser
is being charged
Attenuator
Not required
Gives means beside ON/OFF switch to tempo-
rarily block beam
Location controls
Not required
Controls so located that there is no danger of exposure to AEL above
Classes 1 or 2 when adjustments are made.
Viewing optics
Emission from all viewing systems must be below Class 1 AEL’s as applicable
Scanning
Scan failure shall not cause product to exceed its classification
Class label
Required wording
Figures A and B and specified wording
Aperture label
Not required
Specified wording required
Service entry label
Required as appropriate to the class of accessible radiation
Override interlock label
Required under certain conditions as appropriate to the class of laser used
User information
Operation manuals must contain instructions for safe use
Purchasing and service
information
Promotion brochures must reproduce classification labels; service manuals must contain safety information
Medical products
Special calibration instructions required
Special calibration instructions, means for
measurement and target-indicator required
Fibre optic
Cable service connections require tool to disconnect if disconnection breaks protective housing and permits access
above Class 1