K3NC
K3NC
5
Operation
3
SETTING PROCEDURES
The K3NC has four modes: RUN mode for normal operations, Setting mode for initial parameter input, Protect mode for lock-out configu-
ration, and Maintenance mode for initializing set values. The parameters that are accessible on any individual K3NC will vary depending
on the Output Board installed. Refer to the
K3NC Operation Manual for details.
RUN Mode:
Remains in this mode under normal operation.
The process value can be monitored.
Using the front panel keys, the comparative set value can be changed and counting value reset can be performed.
Setting Mode:
Used for making initial settings.
Includes settings for four menus (Set value (
,ç,â-
), prescaling (
),ä%
), setup (
,â-.)
), option (
()-
)) and the output test.
Protect Mode:
Used for locking the front key operation or parameter changes.
Maintenance Mode:
Used for initializing set values.
Power ON
RUN mode
Setting mode
Maintenance mode
Protect mode
1 s
1 s
+
+
ESC
ESC
ESC
ESC
When power is ON
,ç,â-
- Program set values
,÷åæ'$
Select bank no. of set values
,çõ÷öõ
Enter set value OUT1 of bank 1
,çõ÷öô
Enter set value OUT2 of bank 1
,çõ÷öó
Enter set value OUT3 of bank 1
,çõ÷öò
Enter set value OUT4 of bank 1
,çõ÷öñ
Enter set value OUT5 of bank 1
Note: The above is an example when the bank number is set to 1.
),ä%
- Display prescaling
)÷åæ'$
Select bank no. of prescale values
),õ÷æ0
Set the mantissa (X) of the prescale value
),õ÷æ1
Set the exponent (Y) of the prescale value
ãâä)÷õ
Select decimal point
Note: The above is an example when the bank number is set to 1.
)+(-
- Program lock-out configuration
æ%%
Enable all key protection
,ç,â-
Enable set value change prohibition
+â,â-
Enable prohibition of counting value reset using
the front panel keys
,âä+
Specify the menus to be protected against set-
ting in the setting mode
,â-.)
- Program input mode/input sensor/serial communications
ä(.'-
Specify input mode
"'
Select a sensor type
.ø'(
Enter the unit no. for the host
å),
Select the baud rate
%â'
Select the word bit length
,å"-
Select the stop bits
)+-1
Select the parity bits
()-
- Supplementary settings related to display or control
&â&(
Select power failure memory function
ä(&)'
Set compensation value
ä('ø)
Select conditions that allow compensation input
(.-
Select output mode
%,â-÷!
Enter the upper limit (H) of linear output range
%,â-÷%
Enter the lower limit (L) of linear output range
+ø%
Select the remote/local programming
-â,-
- Generating simulated input for testing the output function