1/32 DIN Digital Panel Meter
K3GN
F-7
D
igi
ta
l pa
n
e
l
in
di
c
a
tors
■
Characteristics
■
Input Ranges: Measurement Range and Accuracy
Note: The shaded ranges indicate default settings.
Item
K3GN-ND
With DC voltage, DC current, and NPN input
K3GN-PD
With DC voltage, DC current, and PNP input
Input signal
DC voltage/current (4 to 20 mA, 1 to 5 V,
±
5 V,
±
10 V)
No-voltage contact (30 Hz max. with ON/OFF pulse width of 16 ms min.)
Open collector (5 kHz max. with ON/OFF pulse width of 90
μ
s min.)
Displayable range
5 digits (-19999 to 99999)
Sampling period
250 ms
Display refresh period
Sampling period (sampling times multiplied by number of averaging times if average processing is selected.)
Comparative output response
time
(transistor outputs)
750 ms max. (transistor output)
(The time required for the judgment output to be output if the input signal rapidly changes from 15% to 95% or from 95% to 15%.)
Linear output response time
750 ms max. (The time required for the analog output to be
output if the output signal rapidly changes from 15% to 95% or
from 95% to 15%.)
---
Insulation resistance
20 M
Ω
min. (at 500 VDC) between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
Dielectric strength
1,000 VAC for 1 min between external terminal and case.
Noise immunity
±
480 V on power supply terminals in normal mode,
±
1,500 V in common mode,
±
1
μ
s, or 100 ns for square-wave noise with 1 ns
Vibration resistance
Vibration frequency: 10 to 55 Hz, Acceleration: 50 m/s
2
for 10 min each in X, Y, and Z directions
Shock resistance
Models with transistor outputs: 150 m/s
2
three times each in 3 axes, 6 directions
Models with contact outputs: 100 m/s
2
three times each in 3 axes, 6 directions
Weight
Approx. 100 g (Main Unit only)
Degree of
protection
Front panel
NEMA4X for indoor use (equivalent to IP66),
Rear case
IP20
Terminals
IP00 and finger protection (VDE0106/100)
Memory protection
Non-volatile memory (EEPROM) (possible to rewrite 100,000 times)
Approved standards
UL508, CSA C22.2 No. 142
EMC
(EMI)
EN 61326
Industry
Emission Enclosure:
EN55011 Group 1 class A
(EMS)
EN 61326
Industry
Immunity ESD:
EN 61000-4-2:
4 kV (contact discharge)
8 kV (air discharge)
Immunity RF-interference:
EN 61000-4-3:
10 V/m (amplitude-modulated,
80 MHz to 1 GHz)
Immunity Fast Transient Noise:
EN 61000-4-4:
2 kV (power line)
Immunity Burst Noise:
1 kV line to line (I/O signal line)
Immunity Surge:
EN 61000-4-5:
2 kV line to ground (power line)
Immunity Conducted Disturbance
EN 61000-4-6:
3 V (0.15 to 80 MHz)
Immunity Power Frequency Magnetic EN 61000-4-8:
30 A/m (50 Hz) continuous time
Input type
in-t
Analog
analg
Pulse
pulse
Remote
rmt
DC
current
input
DC voltage input
Rotary pulse
Analog
range
range
4 to 20
mA
4-20
Analog
range
range
1 to 5 V
1-5
±
5 V
5
±
10 V
10
Pulse
frequency
p-fre
30 Hz
30
5 kHz
5k
Range of display
from
9999
to
99999
using
communications.
Connection
terminal
E
-
F
Connection
terminal
D
-
E
Connection
terminal
B
-
C
Input
impedance
60
Ω
Input
impedance
1 M
Ω
min.
---
---
Measurement
accuracy
±0.1% full scale ± one digit max. (at
23±3
°
C)
±0.1% full scale ± one
digit max. (at 23±5
°
C)
±0.1% full scale ± one digit max. (at
23±5
°
C)
---
Current range
(mA)
20.00
4.00
0.00
Voltage
range (V)
10.00
5.000
0.000
−
5.000
−
10.00
Frequency
range
(Hz)
5000
4000
3000
2000
1000
0.0
5.500
0.000
5.500
−
5.500
22.00
0.00
11.00
−
11.00
30.00
0.05
5000
0