IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

13

USING THE AC ADAPTER

NOTES:

• Use only the authorized Omron AC Adapter that came with

this monitor.

• We recommend you install the batteries even if the AC

Adapter is used. If no batteries are installed, you may need
to reset the date and time if the AC Adapter is disconnected.
The measurement results will not be deleted.

CAUTION

Use only authorized parts and accessories. Parts and accessories not
approved for use with the device may damage the unit.

- DANGER -

TO REDUCE THE RISK OF 

FIRE OR ELECTRIC SHOCK,

CAREFULLY FOLLOW THESE INSTRUCTIONS.

For connection to a power supply not in the U.S.A., use an
attachment plug adapter of the proper configuration for the
power outlet.

The power unit (AC Adapter) is intended to be correctly
oriented in a vertical or floor mount position.

BP755IM_E_SP_q6_R2.qxd  5/26/09  4:14 PM  Page 13

Содержание INTELLISENSE BP755

Страница 1: ...Automatic Blood Pressure Monitor with ComFit Cuff Model BP755 INSTRUCTION MANUAL BP755 ESPAÑOL ENGLISH ...

Страница 2: ...ular Heartbeat Symbol 10 Movement Error Symbol 10 Average Value Symbol 10 Heartbeat Symbol Hypertension Indicator 11 Using the AC Adapter 13 Battery Installation 15 Setting the Date and Time 17 Applying the Arm Cuff 20 Taking a Measurement 23 Special Conditions 25 Using the Memory Function 26 Care and Maintenance Care and Maintenance 29 Error Indicators and Troubleshooting Tips 31 FCC Statement 33...

Страница 3: ...d of blood pressure measurement This means the monitor detects your blood s movement through your brachial artery and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use The BP755 comes with the following components Monitor ComFit Cuff AC Adapter Storage Case Quick Start Guide Instruction Manual printed in English and S...

Страница 4: ...t in minor or moderate injury to the user or patient or damage to the equipment or other property OPERATING THE DEVICE Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider The monitor is not intended to be a diagnostic device If battery...

Страница 5: ...not use the device for any other purpose Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution Do not use a cellular phone near the device It may result in an operational failure Use only authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit Us...

Страница 6: ...opping the unit on the floor Do not submerge the device or any of the components in water Store the device and the components in a clean safe location Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components ...

Страница 7: ... your left arm on a table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Wait 2 3 minutes between measurements The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement You may need to increase the wait time depending on your individual physiological characteristics 8 Keep a record of you...

Страница 8: ...e Time Setting Button Display AC Adapter Jack Components Arm Cuff Air Tube Air Plug Connects to Air Jack AC Adapter Storage Case Thumb Grip Operating Instructions Instruction Manual Automatic Blood Pressure Monitor with ComFit Cuff Model BP755 INSTRUCTION MANUAL BP7 55 Housing Cord Quick Start Guide ...

Страница 9: ...od Pressure Systolic Blood Pressure Memory Symbol Pulse Display Date Time Display Battery Low Indicator Average Value Symbol Heartbeat Symbol Hypertension Indicator Deflation Symbol Movement Error Symbol Irregular Heartbeat Symbol ...

Страница 10: ...d pressure If the irregular heartbeat symbol displays with your measurement results we recommend you consult your physician Follow the directions of your doctor MOVEMENT ERROR SYMBOL The Movement Error Symbol is displayed if you move your body during the measurement Please remove the arm cuff and wait 2 3 minutes reapply the arm cuff and take another measurement AVERAGE VALUE SYMBOL The Average Va...

Страница 11: ...plete the Heartbeat Symbol flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and or above 85 for the Diastolic Blood Pressure value USING THE MEMORY FUNCTION The Heartbeat Symbol flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and or above 85 for the Diasto...

Страница 12: ...ain patients including diabetic patients pregnant women and patients with renal failure1 WARNING The monitor is not intended to be a diagnostic device WARNING Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider Omron Healthcare recomme...

Страница 13: ...er is disconnected The measurement results will not be deleted CAUTION Use only authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit DANGER TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK CAREFULLY FOLLOW THESE INSTRUCTIONS For connection to a power supply not in the U S A use an attachment plug adapter of the proper configuration for the pow...

Страница 14: ...ect the AC Adapter Hold and pull the housing to remove the AC Adapter from the electrical outlet Do not remove by pulling the cord Remove the AC Adapter plug from the monitor WARNING Do not plug or unplug the power cord into the electrical outlet with wet hands CAUTION Do not overload power outlets Plug the device into the appropriate voltage outlet 14 USING THE AC ADAPTER Housing Cord ...

Страница 15: ...e battery cover and slide the cover off in the direction of the arrow 2 Install 4 AA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated NOTE 4 AA size batteries are not included in this unit 3 Replace the battery cover 15 BATTERY INSTALLATION ...

Страница 16: ...r Contact a physician immediately NOTES Turn the unit off before replacing the batteries If the batteries are removed while the unit is still on the date and time will be reset to that of the previous use However the measurement results are not deleted When the batteries are replaced you may need to reset the date and time If the year is flashing on the display screen refer to Setting the Date and...

Страница 17: ...me The year flashes on the display 2 SETTING THE YEAR The year can be set between 2006 and 2030 When the display reaches 2030 it will return to 2006 Press the Memory Up button to advance by increments of one year Press the Date Time Setting button to set the current year The month flashes on the display NOTES Press the Memory Down button to decrease the day and time values by increments of one Pre...

Страница 18: ...HE DAY Press the Memory Up button to advance by increments of one day Press the Date Time Setting button to set the current day The hour flashes on the display 5 SETTING THE HOUR The time is set using AM or PM Press the Memory Up button to advance by increments of one hour Press the Date Time Setting button to set the current hour The minutes flash on the display SETTING THE DATE AND TIME ...

Страница 19: ...e minute Press the Date Time Setting button to set the current minute The year flashes on the display 7 TO TURN THE MONITOR OFF Press the START STOP button NOTE The monitor will automatically turn off after the minute has been set after battery replacement SETTING THE DATE AND TIME ...

Страница 20: ...nded for use in measuring blood pressure and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions APPLYING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit 2 Remove tight fitting clothing from your upper arm STOP START MEMORY APPLYING THE ARM CUFF 20 ...

Страница 21: ...to your left upper arm so the blue stripe is on the inside of your arm and aligned with your middle finger The air tube runs down the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow APPLYING THE ARM CUFF Thumb Grip Cloth Fastening 1 2 inch 1 2 cm Air Tube Blue Stripe Left Arm ...

Страница 22: ... arm use this instruction for Step 5 Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm The bottom of the cuff should be approximately 1 2 above your elbow NOTE Be careful not to rest your arm on the air tube This will restrict the flow of air to the cuff 22 APPLYING THE ARM CUFF Thumb Grip Right Arm ...

Страница 23: ...n a higher inflation may be necessary the monitor automatically re inflates the cuff up to 30mmHg higher than the initial inflation and restarts the measurement 1 Sit on a chair with your feet flat on the floor Place your arm on a table so the cuff is level with your heart TAKING A MEASUREMENT ...

Страница 24: ...ain still and do not move your arm until the entire measurement process is completed NOTE To stop the inflation or measurement push the START STOP button The monitor will stop inflating start deflating and will turn off 3 Inflation stops automatically and the measurement is started As the cuff deflates decreasing numbers appear on the display and the Heartbeat Symbol flashes TAKING A MEASUREMENT 2...

Страница 25: ...N Inflating to a higher pressure than necessary may result in bruising where the cuff is applied If your systolic pressure is known to be more than 220 mmHg press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure NOTES Do not apply more pressure than necessary The monitor will not inflate above 299 mmHg When the measurement is compl...

Страница 26: ...alculates the average reading based on the three most recent sets of measurement values taken within 10 minutes of the most recent reading TO DISPLAY THE AVERAGE VALUE AND THE MEASUREMENT VALUES NOTE If two sets of measurement values are stored in the memory for the 10 minute period the average is based on the two sets of measurement values If one set of measurement value is stored this is display...

Страница 27: ... display the oldest set of measurement values NOTES The date and time are alternately displayed with the measurement values Press the button repeatedly to display the next values Press and hold the button to display the values faster 3 Press the START STOP button to turn the power off USING THE MEMORY FUNCTION Alternating display ...

Страница 28: ... deleted 1 While holding the Memory Down button press the START STOP button down for more than 2 seconds until the display appears as it does in the following illustration 2 Press the START STOP button to turn the monitor off NOTE The monitor will automatically turn off after five minutes 28 USING THE MEMORY FUNCTION ...

Страница 29: ...ot attempt to clean the cuff CAUTION Do not submerge the device or any of the components in water Do not subject the monitor to extreme hot or cold temperatures humidity or direct sunlight CAUTION Store the device and the components in a clean safe location CAUTION Do not subject the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the unit will not be used f...

Страница 30: ...s manual CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit CAUTION Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components ...

Страница 31: ...l until the measurement is complete Cuff under inflated Cuff not applied correctly Remove the arm cuff Read Taking a Measurement Wait 2 3 minutes Take another measurement Cuff over inflated Batteries are worn Replace the four batteries Refer to Battery Installation ERROR INDICATORS ANDTROUBLESHOOTINGTIPS ...

Страница 32: ... with new ones Check the battery installation for proper placement of the battery polarities Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of day how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement ...

Страница 33: ...y one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does...

Страница 34: ...and the return shipping and handling fee Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF ME...

Страница 35: ... batteries Battery Life Approx 1500 uses with 4 new alkaline batteries Operating Temperature 50ºF to 104ºF 10ºC to 40ºC 15 to 90 RH Humidity Storage Temperature 4ºF to 140ºF 20ºC to 60ºC 10 to 95 RH Humidity Air Pressure 700 1060 hPa Main Unit Weight Approximately 12 1 2 oz 355 g not including batteries Main Unit Dimensions Approx 6 3 32 l x 5 5 32 w x 3 5 16 h 155 mm x 131 mm x 84 mm Cuff Size Ap...

Страница 36: ...Manufactured by OMRON HEALTHCARE Made in China Distributed by OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Copyright 2009 Omron Healthcare Inc ...

Отзывы: