background image

9

English

8

10~15mm

4) Place the cuff over your left wrist with your thumb facing upwards.
Leave app 10-15 mm between the cuff and the bottom of the palm of your
hand as shown in the  figures.

1

2

4) Pull the wrist cuff upward and close the cuff firmly with the Velcro tape 
as shown.

You can use your 637IT also on your right hand after selecting right wrist
measurement in the SETTING MODE.

People with a slender wrist (wrist circumference of less than 145mm) may
feel loose because the cuff may not be wrapped firmly. Please do not force
the cuff it will not affect the measurement.

3

Correct Posture

Incorrect Posture

How to obtain a correct posture

Achieving a correct posture before measuring your blood pressure is important since an incorrect
posture might give you incorrect readings. To achieve a correct posture please follow the instructions
(see pictures):
1) Sit down and stretch your back.
2) Relax yourself by relieving the stress from your shoulders and arms.
3) Breath several times deeply and return to natural respiration.
4) Do not sustain your wrist with your other hand and avoid stress in your hand by making firm grips
or large extensions.

Measuring your blood pressure and pulse

If you have achieved the correct posture you can start the measurement. When you measure for the
first time the Position Sensor and the Signal will be ON and measuring at the left wrist will be pre set.

• Push the O/I button to activate your 

637IT and the Position Sensor 
Screen will be displayed.

Содержание INTELLI 637IT

Страница 1: ...dig automatische bloeddrukmeter voor de pols Manuel d instructions 637IT Tensiomètre entièrement automatique pour prise de mesure au poignet Manual de instrucciones 637IT Aparato completamente automático para medir la presión arterial en la muñeca Manuale di instruzioni 637IT Misuratore della pressione per il polso completamente automatico English Deutsch Nederlands Français Italiano Español 637IT...

Страница 2: ...ing signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk of damage to you and others The icons and meanings are shown as follows Warning sign Contents Indicates matters in which bodily harm or material damage may arise as a result of incorrect handling Caution The icon indicates prohibitions what you cannot do Matters invol...

Страница 3: ...measure their own blood pressure in consultation with their doctor since the readings may be changed by the pregnancy Please remember Self measurement is not the same as medical treatment You should never change the dose of medicines as prescribed by your doctor Before using your OMRON 637IT for the first time Your blood pressure monitor the benefits The OMRON 637IT is a compact fully automatic wr...

Страница 4: ... How to Set the Date and Time Before using your OMRON 637IT for the first time you have to set the date and time After turning the monitor on by pushing the O I button the initial screen see picture will be available for a few seconds After the initial screen you will proceed automatical ly to the TIME SET screen For instruction how to set the date and time refer also to page 16 in Chapter How to ...

Страница 5: ...sture Achieving a correct posture before measuring your blood pressure is important since an incorrect posture might give you incorrect readings To achieve a correct posture please follow the instructions see pictures 1 Sit down and stretch your back 2 Relax yourself by relieving the stress from your shoulders and arms 3 Breath several times deeply and return to natural respiration 4 Do not sustai...

Страница 6: ...asurement is finishes the deflation mark flashed and the cuff deflates How to enlarge the reading The results will be shown on your display By pushing the buttons you can enlarge the readings How to Use the Memory Function Date and Time of Measurement Your OMRON 637IT blood pressure monitor is able to store maxi mum 90 measurements including date and time When your blood pressure monitor is holdin...

Страница 7: ...n of Data in Flashing Display Display screen where the systolic blood pressure values higher than 170 mmHg are measured twice Graph Display Screen of Hypertension Type The systolic blood pressure is higher than 170mmHg When a systolic blood pressure above 170 mmHg is measured twice the symbol is displayed in the graph When a systolic blood pressure above 170 mmHg is measured three times the sym bo...

Страница 8: ...itched ON or OFF In the factory preset the position sensor is enabled If the position sensor is switched ON you can choose to have the optimal wrist height supported by an acoustic sound SIGNAL ON or OFF Measuring Wrist Screen Measuring Wrist Right Wrist Screen Left or right wrist measurement Normally blood pressure is measured on the left wrist factory preset With your OMRON 637IT you can choose ...

Страница 9: ...rmation by selecting YES all the settings will be changed to the factory mode The monitor will return to the AUTO MEMORY SCREEN You can turn off your monitor by pushing the O I button How to use the computer interface This blood pressure monitor has a computer interface and is supplied with software to transfer the memory of the blood pressure monitor to your personal computer Required operating e...

Страница 10: ...ble to transfer the memory of your 637IT blood pressure monitor to your personal computer By pressing the TIME button you are able to set the date and time in your 637IT blood pressure monitor By pressing the ID button you are able to set your personal name in your 637IT blood pressure monitor By pressing the CLOSE button you are closing the program How to set the time Press the TIME button on you...

Страница 11: ...ressure Optimal blood pressure target value Normal blood pressure Normal systolic value Mild hypertension Moderate hypertension Severe hypertension Hypertension guide The World Health Organization WHO and the International Society of Hypertension ISH estab lished the Blood Pressure Classification Use this Classification as the guide to know the state of your blood pressure However if you are conce...

Страница 12: ...spirits thinners or similar solvents Stains on the cuff can be carefully removed using a moist cloth and soapy water Do not wash the cuff or make it wet Please make sure no water will enter the main unit Keep your monitor in the storage case protected from extreme temperatures and humidity Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON dealer or dis tributor Pl...

Страница 13: ...the above mentioned measures please contact the nearest OMRON dealer or distributor Spare parts and accessories OMRON considers due to the used high company and quality standards the main unit as a non serviceable part because of the necessity of proper calibration after replacement of high tech components The cuff can be replaced by an authorised expert Specifications Name OMRON Fully Automatic B...