Temperature Controller CompoWay/F Driver
GP-Pro EX Device/PLC Connection Manual
41
Command code list
Variable
Areas
CD0000.00-CD0039.31
CD0100.00-CD0139.31
CD0200.00-CD0239.31
CD0300.00-CD0339.31
CD0000-CD0039
CD0100-CD0139
CD0200-CD0239
CD0300-CD0339
Double Word Device
CE0000.00-CE0039.31
CE0100.00-CE0139.31
CE0200.00-CE0239.31
CE0300.00-CE0339.31
CE0000-CE0039
CE0100-CE0139
CE0200-CE0239
CE0300-CE0339
Double Word Device
CF0000.00-CF0039.31
CF0100.00-CF0139.31
CF0200.00-CF0239.31
CF0300.00-CF0339.31
CF0000-CF0039
CF0100-CF0139
CF0200-CF0239
CF0300-CF0339
Double Word Device
D00000.00-D00039.31
D00100.00-D00139.31
D00200.00-D00239.31
D00300.00-D00339.31
D00000-D00039
D00100-D00139
D00200-D00239
D00300-D00339
Double Word Device
D10000.00-D10039.31
D10100.00-D10139.31
D10200.00-D10239.31
D10300.00-D10339.31
D10000-D10039
D10100-D10139
D10200-D10239
D10300-D10339
Double Word Device
D20000.00-D20039.31
D20100.00-D20139.31
D20200.00-D20239.31
D20300.00-D20339.31
D20000-D20039
D20100-D20139
D20200-D20239
D20300-D20339
Double Word Device
D30000.00-D30039.31
D30100.00-D30139.31
D30200.00-D30239.31
D30300.00-D30339.31
D30000-D30039
D30100-D30139
D30200-D30239
D30300-D30339
Double Word Device
Operation
command
*6
-
A0000-A000D
Word Device
*5
*1
Available variable area range varies depending on the using Temperature Controller. Refer to the manual of
OMRON Temperature Controller for setting.
*2
When you write the bit address, the Display reads the word address corresponding to that of the External Device
first. Then, it changes the target bit address among the word data once read and returns the word data to the
External Device. Note that the correct data may not be written if you change the word address value in the ladder
program while the Display reads the data of the External Device and returns it to the External Device.
*3
Write disable
*4
When writing, switch the setting area of the Temperature Controller to setting area 1.
*5
Read disable
*6
When executing the operation command (write), specify the directive code for the device address. Set the
related information for the writing value. Set the related information in hexadecimal number, such as 0x00,
0x01. Set the device code to be used in the painting software as A, and enter each command code instead of the
device address.
Command
code
Related information
Command comment
Device address
Higher
byte
Lower byte
00
0
*1
0: OFF (Disabled)
1:ON (Enabled)
Communication writing
A0000
continued to next page
Device
Bit Address
Word Address
32bit
Remarks