3-10-3
AC Connections
The 200-240 VAC High Power connector is located on the Primary Interface Panel.
Use the illustrations below to understand the AC connections for single and three-phase power sour-
ces.
A retaining clip is provided to secure the High Power connector to the Primary Interface Panel. To in-
stall this retaining clip, insert the posts into the Primary Interface Panel, align the holes horizontally,
and then insert the retaining clip by squeezing it and then placing it into the post holes. Posts may
need to be adjusted to ensure a tight High Power connector fit.
Additional Information
A connector, pins, and retaining clip are included with the robot. The part number for this as-
sembly is 22822-100.
Primary Interface Panel
1 Φ, 200-240 VAC
1 Φ
200-240 VAC
Line
Neutral
Earth Ground
12 A Fuse / Breaker
Slow-blow Type
Primary Interface Panel
1 Φ, 200-240 VAC
3 Φ
200-240 VAC
Line 1
Line 3 (unused)
Earth Ground
12 A Fuse / Breaker
Slow-blow Type
Line 2
200-240 VAC
3 Installation
3-45
i4H Robots User's Manual (I660)
3-10
Supplying Power and Ground
3
3-10-3
AC Connections
Содержание i4-650H
Страница 1: ...i4H Robots User s Manual i4 650H i4 750H i4 850H I660 E 02...
Страница 6: ...Manual Information 4 i4H Robots User s Manual I660...
Страница 74: ...2 Specifications 2 20 i4H Robots User s Manual I660...
Страница 142: ...5 Troubleshooting 5 6 i4H Robots User s Manual I660...
Страница 176: ...Appendix A 16 i4H Robots User s Manual I660...
Страница 177: ...I Index I 1 i4H Robots User s Manual I660 I...
Страница 180: ...Index I 4 i4H Robots User s Manual I660...
Страница 181: ......