Precautions for Correct Use
• It is safe to connect or disconnect the power cord from the Docking Target or battery without
powering OFF the Power Supply Box.
• Always wait until the green OPERATION LED indicator on the Power Supply Box is ON solid
before attempting to charge a battery.
• Do not press the Service button on the Power Supply Box if the yellow DC POWER LED indi-
cator is flashing when there is no battery connected. Contact your OMRON representative if
this condition is present.
Additional Information
Refer to
on page 4-23 for more information.
The following table provides descriptions of each LED state.
LED
State
Description
AC POWER
Blue ON
AC supply power is detected.
Blue OFF
AC supply power is not detected.
OPERATION
Green ON
No load battery detected. Normal
operation and ready to charge
Green OFF
Charging not possible.
Green flashing
Service mode active.
DC POWER
Yellow ON
Charging.
Yellow OFF
Not charging.
Yellow flashing
An absolutely depleted battery has
been detected.
ERROR
Red OFF
No error is present.
Red ON
A non-critical error is present
.
Red flashing
.
*1.
When no battery load is connected, the green OPERATION indicator can take up to 60 seconds to turn ON
while the system performs diagnostics.
*2.
on page 5-6 for more information.
Docking Target
The Docking Target provides an easily identifiable target for the AMR to locate when aligning for
charging.
The AMR travels at a low speed when approaching the Docking Target in preparation for engaging
with the charging paddle.
When the AMR successfully engages the charging paddle and the Power Supply box determines
charging is possible, charging will automatically begin.
4-11-4
Charging the Battery
A battery can be charged while inside the AMR or outside (removed from) the AMR.
Charing automatically begins when the Power Supply Box detects a connected battery, either inside
the AMR when it is engaged with the Docking Target or when a battery is removed from the AMR and
directly connected to the Power Supply Box.
4 Operation
4-23
HD-1500 Platform User's Manual (I645)
4-1
1 Battery and Charging
4
4-1
1-4
Charging the Battery
Содержание HD-1500 Platform
Страница 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Страница 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Страница 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Страница 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Страница 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Страница 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Страница 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Страница 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Страница 255: ......