background image

⑤ 

Set the ON time (the time when pulse-output
operation starts) to 8:25 am using the       and
               Keys. 

⑦ 

Press the            key to enter the operation 
date setting mode. 

Note

Up to 24 sets of settings are possible. 

Switching between timer operation and pulse-output operation will clear the 
operation start time, operation day, and pulse width settings. 

pulse-output operation and timer operation cannot be used at the same time. 

⑨ 

Press the             Key. The Time Switch will 
enter run mode and operation based on the
settings will start. 

⑥ 

Press the           Key. 
(Repeat steps 

 and 

to make other settings if necessary.) 

- 14 -

The color indicates flashing 

⑧ 

Move the

 ▼ 

symbol to Saturday (or Sunday)

using the       Key. Clear the operation day 
indicator (     ) by pressing the           Key.

Lit (Operation Day)
Not LIt (Non-operation Day)

WRITE

WRITE

WRITE

WRITE

MODE

MODE

h

d

m/ 

P

 WD

8 25

1

P 

P

AM

PW

-- --

2

P 

P

PW

P 

P

PW

P 

P

PW

7 30

25

8

AM

P

AM

● 

● 

PW

SU MO TU WE TH FR SA

SU MO TU WE TH FR SA

SU MO TU WE TH FR SA

SU MO TU WE TH FR SA

SU MO TU WE TH FR SA

Содержание H5F -

Страница 1: ... using the product Please operate the product by the qualified specialist having the electrical know how Read this instruction manual with enough and use the product with enough understanding Keep this instruction manual close at hand and use it for reference during operation 1617398 8D OMRON Corporation English H5F TIME SWITCH 500 300 PW ON PM PM 15A 10A RES 4 3 2 1 250VAC 24VDC 100 to 240VAC 50 ...

Страница 2: ...rs must perform Warning against rupture Notification of possible rupture under certain conditions Warning against electric shocks Notification of possible electric shocks under certain conditions General warning Notification of general unspecified prohibition items Key to Warning Symbols CAUTION Indicates information that if not followed could result in relatively serious or minor injury property ...

Страница 3: ...risk of fire Before changing times or other settings while power is being supplied either turn OFF the power on the load side or set the Out ON OFF switch to OFF and confirm the safety of the system Tighten the terminal screws securely The recommended tightening torque is 8 67 in lb 0 98 N m 10 4 in lb max 1 17 N m max Loose screws may result in fire or malfunction Never disassemble repair or modi...

Страница 4: ...es of internal components 6 Do not use the Time Switch in environments subject to shocks or vibration beyond the ranges specified in this document 7 Do not use the Time Switch in dusty environments in locations where corrosive gases are present or in locations subject to direct sunlight 8 Store at the specified temperature If the Time Switch has been stored at a temperature of less than 10 allow t...

Страница 5: ...ON an inrush current will flow for a short time approx 2 A for 0 3 ms at 264 VAC Depending on the power supply capacity operation may not start Be sure to use a power supply with a sufficient capacity and a breaker 8 None of the Time Switch components are user replaceable including the battery Precautions for Correct Use Suitability for Use OMRON shall not be responsible for conformity with any st...

Страница 6: ... Selecting the mode 4 Setting the time 5 Setting timer operation 6 Setting pulse output operation 7 Setting partial operation on specified day 8 Changing Confirming settings 9 Clearing the settings 10 Setting Temporary Holidays 11 Summer time DST 12 Switching between 12 hour am pm and 24 hour Display 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 22 5 Table of Contents ...

Страница 7: ...ower supply is OFF 16 Setting precautions 17 Setting examples 18 Troubleshooting 23 24 25 26 26 27 28 1 Dimensions and mounting dimensions 2 Connections 3 Wiring 4 Output built in relay life expectancy 5 Ratings and performance characteristics 6 EN IEC standards 7 Record of settings 23 24 31 31 32 33 33 34 34 ...

Страница 8: ...n be executed by using this key in combination with the Write Key 1 Nomenclature ON PW SU MO TU WE TH FR SA OUT OUT ON AUTO OFF POWER TMR P CLR 1h HOLYDAY TEST SELECT d WRITE m PWD MODE h Pulth Width Unit Indicator Partial operation on specified day Indicator Current Day Indicator Summer Time Indicator Lit when the Time Switch is set to summer time Operation Setting Mode Indicator Next Operation I...

Страница 9: ...operate When that day has passed operation will continue according to the regular settings and the Time Switch will operate as normal on that day from the following week This function can be used with pulse output operation Holiday Control output is continuously held in the ON state regardless of the settings using the Out ON OFF switch Forced ON OFF Operation Output turns ON for a fixed period pu...

Страница 10: ...lse operation Refer to page 11 Set confirm change or clear the operation day and specified day settings Refer to page 11 MODE HOLIDAY 9 Program check function test 2 s min 1 s min TEST Note 1 TEST TEST The days and times when output will actually turn ON OFF are displayed chronologically Refer to page 25 Note 1 After the last item is displayed the mode automatically returns to run mode Note 2 At t...

Страница 11: ...eturn to the run mode h Press the Key The colon will flash and the clock will start from 0 s WRITE The color indicates flashing factory setting At the time of delivery the mode is run mode and there is no current time setting before making any other settings press the Key for 1 s min to enter time adjustment mode and set the current time using the above procedure Display of factory setting 4 Setti...

Страница 12: ... the operation setting time display will flash to indicate an error Set the OFF time to 5 15 pm using the and Keys SU MO TU WE TH FR SA 8 30 am 5 15 pm 11 The color indicates flashing Non operation Day Non operation Day Operation Day Operation Day Operation Day Operation Day Operation Day 5 Setting Timer Operation MODE h h m P WD m P WD WRITE 1 P PW 8 30 1 P AM PW 1 P PW 5 15 1 P PM PW SU MO TU WE...

Страница 13: ...ore than 24 hours is possible by combining 2 or more sets of settings Refer to pages 26 and 27 pulse output operation and timer operation cannot be used at the same time Refer to page 13 Press the Key The Time Switch will enter run Mode and operation based on the settings will start Press the Key Repeat steps 2 to 5 to make other settings if necessary 12 The color indicates flashing Lit Operation ...

Страница 14: ...he time of delivery Set the pulse width to 30 s using the Key The pulse width can be set in the range 1 to 59 s or 1 to 60 min 8 25 am 30s 13 P Enter operation time setting mode using the Key The symbol flashes The color indicates flashing 6 Setting pulse output operation MODE WRITE SU MO TU WE TH FR SA Non operation Day Non operation Day Operation Day Operation Day Operation Day Operation Day Ope...

Страница 15: ... used at the same time Press the Key The Time Switch will enter run mode and operation based on the settings will start Press the Key Repeat steps and to make other settings if necessary 14 The color indicates flashing Move the symbol to Saturday or Sunday using the Key Clear the operation day indicator by pressing the Key Lit Operation Day Not LIt Non operation Day WRITE WRITE WRITE WRITE MODE MO...

Страница 16: ...me for the specified day to 8 30 am using the and Keys SELECT Press the Key S 8 30 am to 0 30 pm Specified Day Operation 1 15 pm to 5 15 pm 15 Enter operation time setting mode using the Key The color indicates flashing 7 Setting partial operation on specified day MODE h h WRITE SU MO TU WE TH FR SA Specifird Day Non operation Day Operation Day Operation Day Operation Day Operation Day Operation D...

Страница 17: ... The Time Switch will enter run mode and operation based on the settings will start The operation day indicator of the specified day will flash Press the Key Set the time to 1 15 pm using the and Keys 16 The color indicates flashing Lit Operation day Not lit Non operation day Flashing Specified day Press the Key Set the time to 5 15 pm using the and Keys Press the Key Press the Key to enter operat...

Страница 18: ...Press the Key to enter operation date setting mode The operation dates will be displayed Make changes if necessary using the and Keys 17 Enter operation time setting mode using the Key The ON time for program No 1 will be displayed Note Operation based on the changed settings will start as soon as the Time Switch returns to run mode The color indicates flashing 8 Changing Confirming Settings MODE ...

Страница 19: ...and key 18 Press the key to enter operation date setting mode The operation dates will be displayed Make changes if necessary using the and key Note Operation based on the changed settings will start as soon as the Time Switch returns to run mode The color indicates flashing Enter operation time setting mode using key The pulse width is displayed MODE MODE MODE m P WD m P WD WRITE WRITE h WRITE d ...

Страница 20: ...just one operation Output is temporarily maintained by the condition before setting is cleared CLR Press the Key twice The Time Switch will enter run mode and operation based on the new settings will start The color indicates flashing Enter operation time setting mode using Key The ON time for program No 1 will be displayed 9 Clearing the Settings MODE MODE WRITE 8 30 1 P S AM ON PW 1 15 2 P PM ON...

Страница 21: ...led if the Key is released while clr is still flashing and only the settings for the display program will be cleared 20 The color indicates flashing When all the settings have been cleared the operation time operation day pulse width holiday specified day and partial automatic operation settings will be returned to their factory settings MODE CLR CLR 8 30 1 P S AM ON PW c lr ON PW 1 P PW SU MO TU ...

Страница 22: ...y indicator under the days set as holidays will turn OFF Note Any day in the 7 day period starting from the present day can be set as a holiday When a day set as a holiday has passed the indicator under that day will a utomatically turn ON again Holiday setting mode can be entered from run mode only Operation based on the new settings i e including the holiday setting will start as soon as the Tim...

Страница 23: ...for 2 s min the time display switches between 12 hour am pm and 24 hour display Note Switching is possible only in run mode The factory setting is 12 hour am pm display 2 s min 22 1h The color indicates flashing The color indicates flashing 11 Summer Time DST 12 Switchingbetween12 hour am pm and24 hourDisplay 1h h h 3 30 15 5 PM PM ON PW 4 30 15 5 PM 1h PM ON PW 3 30 15 5 PM PM ON PW 15 30 15 17 O...

Страница 24: ...h to OFF Override and automatic return operation cannot be set or cleared if power is not being supplied to the Time Switch Override and automatic return operation is cleared if any of the settings are changed Example2 Regular setting ON at 8 30 am OFF at 5 15 pm Use the following procedure to stop operation at 3 00 pm for the present day only 8 30 am 5 15 pm 3 00 pm 8 30 am 5 15 pm Present day Ne...

Страница 25: ...d down Point at which the Out ON OFF switch changes from Auto to ON Regular settings Actual output operation Regular settings Actual output operation Regular settings Actual output operation 30min Example2 Override and automatic return operation turned ON while output is OFF pulse width 30 min Example3 Override and automatic return operation turned OFF while output is OFF From the next time onward...

Страница 26: ...ress the Key again to return to run mode before reaching the end of the program check function display sequence The and symbols displayed in test mode have no effect on the present operation Only ON times are displayed for pulse output operation 25 Press the Key for 2 s min in run mode to start program check The display will flash test and the day and time of the next change in output status will ...

Страница 27: ... years min Power interruption rate of 50 The color indicates flashing 2 If there is a switch between timer operation and pulse output operation the operation time operation day and pulse width settings will all be cleared 1 If settings overlap the earliest ON time and the latest OFF time will be used Output will stay ON continuously without interruption If an ON and OFF setting are made for the sa...

Страница 28: ...m 1 00 pm on Monday right through to 8 00 am on Saturday 1 00 pm 1 00 pm to 8 00 am specified operation Specified day MO Operation Day TU WE TH FR 7 00 am to 2 00 pm 7 00 am 2 00 pm 8 00 am Example3 Use the settings given below to turn ON output from 8 00 pm to 7 00 am from Monday to Thursday and from 8 00 pm on Friday right through to 7 00 am on Monday 8 00 pm 8 00 pm to 7 00 am specified operati...

Страница 29: ...influence of noise or surge Separate the Time Switch from any sources of noise The display is incorrect P 7 Is power being supplied to the Time Switch Check that the power is ON using the display Output does not turn ON when the Out ON OFF switch is set to ON P 23 Is the Time Switch set for Override and automatic return operation Clear Override and automatic return operation P 17 25 Is the Time Sw...

Страница 30: ...al or horizontal Panel Y92F 30 Flush mounting Adapter accesory Y92A 48E Dust Cover sold separately Cutout sections Cut out as required for wiring Terminal cover accesory M4 tapping screws 2 provided Mounting space Size of tapping screw hole Thickness of a panel Size of hole 0 8 to 1 2mm ø3 6mm 1 6 to 4 0mm ø3 7mm 1 Dimensions and Mounting Dimensions mm mm Terminal cover accesory 48 63 7 84 8 88 7 ...

Страница 31: ... mounting bracket Mounting space Dimensions when using PFP 100N or PFP 50N DIN Track Dimensions when using PFP 100N2 DIN Track Mounting bracket accesory M4 tapping screw hole mm Size of tapping screw hole Thickness of a panel Size of hole 0 8 to 1 2mm ø3 6mm 1 6 to 4 0mm ø3 7mm 50 50 5 25 73 43 1 60 42 101 2 32 68 50 35 3 90 63 1 71 8 76 1 84 8 60 50 5 25 101 15 104 to 106 117 4 73 ...

Страница 32: ...wing diagram Time Switch output As a rough guide the capacitor C and resistor R should have the following specifications C 0 5 to 1 µF for a switching current of 1 A R 0 5 to 1 Ω for a switching voltage of 1 V Use a capacitor with a dielectric strength appropriate for the power supply voltage Use an AC type capacitor with AC circuits There may be cases where due to inconsistencies in the nature an...

Страница 33: ...nto a single terminal Strip length 11 1 mm Applicable tightening torque 8 67 to 10 4 in lb 0 98 to 1 17 N m Recommended fuse T2A AC250V T2A 250 VAC time delay low breaking capacity Power supply internal circuit Load Load Power supply Power supply Power supply Power supply Load H5F Power supply Load Load Power supply Power supply Load H5F H5F H5F H5F Power supply Electromagnetic contactor Electroma...

Страница 34: ... 01 50ms max Total error Note1 100m s 2 Malfunction durability Mechanical durability ON OFF operation 24 12 sets of ON and OFF operations pulse output operation 24 Operations Pulse width 25 to 65 C Avoid freezing or condensation Ambient Storage temparature Ambient operating temparature 5 years min 10 years min Power interruption rate of 50 Note2 MAX 2 000 m Altitude 10 to 55Hz 0 75mm double amplit...

Страница 35: ...ply and outputs Connect the output terminals only to devices without exposed charged parts and with the basic insulation appropriate for the maximum operating voltage For 24VDC input type Connect the power supply terminals only to devices without exposed charged parts and with the basic insulation appropriate for the maximum operating voltage 6 EN IEC Standards 7 Record of Settings 34 ...

Страница 36: ...lisabeth Selbert Strasse 17 40764 Langenfeld GERMANY Phone 49 2173 6800 0 Fax 49 2173 6800 400 FRANCE OMRON ELECTRONICS S a r l 14 rue de Lisbonne 93561 ROSNY SOUS BOIS FRANCE Phone 33 1 5663 7000 Fax 33 1 4855 9086 AUSTRALIA OMRON ELECTRONICS PTY LTD 71 Epping Road North Ryde Sydney NSW 2113 Australia Phone 61 2 9878 6377 Fax 61 2 9878 6981 SINGAPORE OMRON ELECTRONICS PTE LTD 55 Ubi Avenue 1 05 0...

Отзывы: