manualshive.com logo in svg
background image

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. J166-E1-01

1206

OMRON Corporation

Industrial Automation Company

Control Devices Division H.Q.

Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7109/Fax: (81)75-344-7149

Warranty and Application Considerations

Read and Understand this Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any 
questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other 
period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES 
THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS 
OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR 
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, 
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS 
UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND 
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in 
the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING 
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE 
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Disclaimers

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. 
It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual 
performance is subject to the OMRON 

Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your 
OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

Содержание G3NA

Страница 1: ...UL CSA and T V Model Number Structure Model Number Legend 1 Basic Model Name G3NA Solid State Relay 2 Load Power Supply Blank AC output D DC output 3 Rated Load Power Supply Voltage 2 200 VAC or 200...

Страница 2: ...VAC See note 5 to 24 VDC G3NA 250B UTU DC5 24 Photocoupler 100 to 120 VAC G3NA 250B UTU AC100 120 200 to 240 VAC G3NA 250B UTU AC200 240 Phototriac 75 A at 24 to 240 VAC See note 2 5 to 24 VDC G3NA 2...

Страница 3: ...DC 4 to 32 VDC 15 mA max See note 2 4 VDC max 1 VDC min 100 to 240 VAC 75 to 264 VAC 72 k 20 75 VAC max 20 VAC min Model Applicable load Rated load voltage Load voltage range Load current See note 1 I...

Страница 4: ...1 ms max AC input 5 ms max DC input 30 ms max AC input Output ON voltage drop 1 6 V RMS max 1 8 V RMS max 1 6 V RMS max 1 8 V RMS max 1 5 V max Leakage current 5 mA max at 100 VAC 10 mA max at 200 VA...

Страница 5: ...NA 450B UTU Load current A Ambient temperature C With standard heat sink Y92B P250 Without heat sink 50 45 40 30 20 12 10 6 4 2 30 20 0 20 40 60 80 100 20 0 20 40 60 80 100 0 60 50 40 30 20 10 6 0 30...

Страница 6: ...nrush current A peak G3NA 275B UTU G3NA 475B UTU G3NA 290B UTU G3NA 490B UTU 28 30 26 24 22 20 18 16 14 12 10 8 6 4 2 0 2 000 1 000 500 200 300 100 50 70 30 20 10 Energized time ms Inrush current A pe...

Страница 7: ...or M4 holes Load power supply Terminal Arrangement Internal Connections Top View G3NA 275B UTU G3NA 475B UTU G3NA 290B UTU G3NA 490B UTU 16 8 47 5 44 25 8 2 12 4 5 47 6 0 2 1 2 4 3 Mounting Holes Outp...

Страница 8: ...the tab with a screwdriver in the direction of the arrow R99 11 for the G3NA 240B UTU G3NA 250B UTU G3NA 450B UTU 4 6 56 21 12 5 16 8 4 5 Use Mounting Bracket R99 11 so that the G3NA 240B 250B 450B U...

Страница 9: ...les 77 max 100 max 71 max 100 max 75 max Two 3 2 dia holes Mounting Holes Weight approx 400 g Two M4 holes Two 4 4 dia or M4 holes Y92B N150 Heat Sink for the G3NA 240B UTU 35 47 6 5 6 5 4 5 30 90 0 3...

Страница 10: ...0B UTU G3NA 425B UTU G3NA D210B Y92B A150N Low cost Heat Sink for the G3NA 240B UTU The orientation indicated by the external dimensions is not the correct mounting orientation When opening mounting h...

Страница 11: ...is caught in screw For GN3A Relays of 40 A or higher use crimp terminals of an appropriate size for the wire diameter for M5 terminals Do not use any wires with damaged sheaths These may cause electr...

Страница 12: ...tach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel This will reduce the ambient temperature of the SSRs and thus increase reliability Generally each 10 C red...

Страница 13: ...re Use one of the fuses in the following table or one with equivalent or better characteristics Recommended Fuses Reverse Connection The output terminal side of the G3NA D210B is connected to a built...

Страница 14: ...A may malfunction and internal components may be deformed or damaged resulting in failure of the G3NA to operate To prevent the G3NA from abnormal vibration do not install the G3NA in locations or by...

Страница 15: ...Solid State Relays G3NA 15...

Страница 16: ...uct on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HA...

Отзывы: