3
Solid State Relay
G3M
J
CHARACTERISTICS
Item
G3M-102PL-US (-4)
G3M-202P(L)-US (-4)
G3M-203P(L) (-4)
G3M-205P(L) (-4)
Operate time
1 ms max. (1/2 of load power source cycle + 1 ms max. for G3M-202P, G3M-203P, G3M-205P)
Release time
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
2 mA max. (at 100 VAC)
2 mA max. (at 100 VAC)
5 mA max. (at 200 VAC)
1.5 mA (at 200 VAC)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
2,500 VAC, 50/60 Hz for 1 min
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s
2
{approx. 100G}
Ambient temperature
Operating: --30
°
C to 80
°
C (with no icing or condensation)
Storage:
--30
°
C to 100
°
C (with no icing or condensation)
Approved standards
UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535
TÜV R9551055 (EN60950)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 15 g
Approx. 25 g
J
APPROVALS
UL (File No. E64562)/CSA (File No. LR35535)
Input Voltage
SSR Type
Load Rating
5, 12, 24 VDC
With Suffixes 102 and
US or UTU
2 A, 125 VAC, Resistive 250 W, 125 VAC, Tungsten 2 A FLA, 12 A LRA, 125 VAC
With Suffixes 202 and
US
2 A, 250 VAC, Resistive 500 W, 250 VAC, Tungsten 2 A FLA, 12 A LRA, 250 VAC
With Suffixes 202
UTU, UTU-1, and
UTU-2
2 A, 250 VAC, Resistive 250 W, 250 VAC, Tungsten 1 FLA, 6 LRA, 250 VAC
With Suffixes 103 and
US or UTU
3 A, 125 VAC, Resistive 375 W, 125 VAC, Tungsten 1.5 A FLA, 9 A LRA, 125 VAC
With Suffixes 203 and
US or UTU
3 A, 250 VAC, Resistive 750 W, 250 VAC, Tungsten 1.5 A FLA, 9 A LRA, 250 VAC
With Suffix 105
5 A, 125 VAC, Resistive 625 W, 125 VAC, Tungsten 2.5 A FLA, 15 A LRA, 125 VAC
With Suffix 205
5 A, 250 VAC, Resistive 1250 W, 250 VAC, Tungsten 2.5 A FLA, 15 A LRA, 250 VAC