Solid State Relays G3
@
-VD
G3H/G3HD
Output
■
Characteristics
Engineering Data
Load Current vs.
Ambient Temperature
Characteristics
One Cycle Surge
Current: Non-repetitive
Model
Applicable load
Rated load voltage
Load voltage range
Load current
Inrush current
G3H-203SN-VD
G3H-203S-VD
100 to 240 VAC
75 to 264 VAC
0.1 to 3 A
45 A 60 Hz, 1 cycle
G3H-203SLN-VD
G3H-203SL-VD
G3HD-X03SN-VD
G3HD-X03S-VD
4 to 48 VDC
3 to 52.8 VDC
0.1 to 3 A
18 A (10 ms)
Model
G3H-203SN-VD/203S-VD
G3H-203SLN-VD/203SL-VD
G3HD-X03SN-VD/X03S-VD
Operate time
1/2 cycle of load power
1 ms max.
1 ms max.
0.5 ms max.
Release time
1/2 cycle of load power 1 ms max.
2 ms max.
Output ON voltage drop
1.6 V (RMS) max.
1.5 V max.
Leakage current
5 mA max. (at 100 VAC);
10 mA max. (at 200 VAC)
2.5 mA max. (at 100 VAC);
5 mA max. (at 200 VAC)
5 mA max. (at 50 VDC)
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
1,500 VAC, 50/60 Hz for 1 min
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock resistance
Destruction: 1,000 m/s
2
Ambient temperature
Operating: –30
°
C to 80
°
C (with no icing)
Storage:
–30
°
C to 100
°
C (with no icing)
Ambient humidity
45% to 85%
Certified standards
G3H: UL508, CSA C22.2 No. 14, EN60947-4-3
G3HD: UL508, CSA C22.2 No. 14, EN60950
Weight
Approx. 50 g
Ambient temperature (
°
C)
Load current (A)
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
Inr
ush current (A, P
eak)
Energized time (ms)
Energized time (ms)
G3HD-X03SN-VD/X03S-VD
Inr
ush current (A)
G3H-203SN-VD/203S-VD/203SLN-VD/
203SL-VD
G3HD-X03SN-VD/X03S-VD
G3H-203SN-VD/203S-VD/203SLN-VD/
G3H-203SL-VD