7
External
Reference
Tables
222
Measurement
FZ3 User's Manual
1700 + N
(N = 0 to 99)
Judgement condition feature quantity
7
(Label No. 0 to 99)
Get only
-999999999.9999 to 999999999.9999
Defect
No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Defect
Get only
0 to 999
6
Position X
Get only
0 to 99999.9999
7
Position Y
Get only
0 to 99999.9999
8
Defect area
Get only
0 to 999999999.9999
9
Defect gravity X
Get only
0 to 99999.9999
10
Defect gravity Y
Get only
0 to 99999.9999
103
Reflect to overall judgement
Set/Get
0: ON 1: OFF
120
Upper limit of defect size
Set/Get
0:4
1:8
2:12
3:16
4:24
5:32
6:64
121
Lower limit of defect size
Set/Get
0:4
1:8
2:12
3:16
4:24
5:32
6:64
122
Defect judgement
Set/Get
0 to 999
123
Defect color
Set/Get
0: Both, 1: White, 2: Black
124
Area measurement
Set/Get
0: OFF, 1: ON
125
Area meas. LV
Set/Get
0 to 999
126
Area judgement
Set/Get
0 to 999999999.9999
Precise Defect
No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Defect
Get only
0 to 999999999.9999
6
Position X
Get only
0 to 999999999.9999
7
Position Y
Get only
0 to 999999999.9999
8
Area
Get only
0 to 999999999.9999
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...