Communicating through Serial Communication (PLC Link)
FZ3 User's Manual
Command (PLC to Controller)
Command area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
3010
0011
0000
0001
0000
Set command
codes.
+3
0010
0000
0000
0001
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0011
0000
0001
0000
Command code
Store response target command codes.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Restart
Restart the controller.
Important
●
When a restart command is executed, BUSY does not turn off even after the command execution bit turns off.
After a restart command is executed, perform a memory clear of BUSY on the PLC side.
Command (PLC to Controller)
Command area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
F010
1111
0000
0001
0000
Set command
codes.
+3
0010
0010
0000
0001
0000
Response (Controller to PLC)
There is no response because restarting is performed.
Acquiring Scene No.
Acquires the current scene No.
Command (PLC to Controller)
Command area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
1000
0001
0000
0000
0000
Set command
codes.
+3
0020
0000
0000
0010
0000
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...