Menu Tables
404
FQ2 User’s Manual
12-1 Menu Tables
Image Tab Page
Menu command
Description
Setting range
Data
Refer-
ence
Camer
a
set
u
p Focus
The value shown here is used as a refer-
ence when adjusting the focus with the
focus adjustment screw.
---
---
Image mode
Pixel sampling can be applied to the
input image to reduce image input time.
Normal (default) or Fast
Scene
Shutter speed
(Normal mode)
Sets the shutter speed for Normal Mode. For FQ-S3
1/1 to 1/60,000
1/250 to 1/60,000 (for Sensors
with Built-in Lighting)
For FQ2-S1/FQ2-S2
1/1 to 1/50,000
1/250 to 1/50,000 (for Sensors
with Built-in Lighting)
Default: 1/250
Scene
Gain
(Normal mode)
If the gain is high, the image will be
bright. If the gain is low, the image will be
dark.
For FQ-S3
Range: 0 to 10 (default: 0)
For FQ2-S1/FQ2-S2
Range: 16 to 64 (default: 16)
Scene
Brightness
(HDR mode)
Sets the brightness level of the image for
HDR Mode.
1 to 100
Scene
HDR
Suppresses reflections and differences
in brightness.
OFF(default), Level 1 to Level4
Scene
Brightness correc-
tion
Use to stabilize the brightness.
ON or OFF (default)
Scene
White balance
Corrects differences in coloring between
the image and the actual object.
• AUTO
• R: 0.001 to 7.999
• G: 0.001 to 7.999
• B: 0.001 to 7.999
Scene
Partial input
Used to make the image input range
smaller.
FQ-S
@@@@@@:
752
×
8 to 752
×
480
FQ-S
@@@@@@
-08
@:
928
×
8 to
928
×
828
FQS3
@:
1280
×
8 to 1280
×
1024
Scene
Rotate 180
You can rotate the Camera image by
180
°
.
ON or OFF (default)
Scene
Calibration setting
Sets a registered calibration pattern.
Unregistered (default), New Calibra-
tion, or Calibration Data 0 to 31
Scene
Li
ght
ning cont
rol Strobe output delay
Sets the delay time for the strobe output
signal (STGOUT) in response to the trig-
ger signal.
0 to 65,535
μ
s (default: 0
μ
s)
Scene
Strobe output time
Sets the output time of the strobe output
signal (STGOUT).
0 to 65,535
μ
s (default: 1,000
μ
s)
Scene
Tr
ig
g
e
r s
e
tu
p Trigger delay
Adjusts the time until the Camera shutter
opens after the trigger signal is received.
0 to 163 ms (default: 0)
System
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......