Inspecting with the Edge Width Inspection Item
130
FQ2 User’s Manual
Measurement Data That Can Be Logged for Edge Width
The following values can be logged as measurement data.
*1 When logging data is output, the data is output in the order of the above table. If more than one item is stored, results are output for each
model.
7-6 Logging Measurement Data and Image Data: p. 208
Errors
Errors in Teaching
A teaching error message will appear if the edge position cannot be detected when teaching. Perform the
following.
• If the color of the measurement object has changed from the specified color, set the color again and try
teaching again.
• If there is an edge and it cannot be detected, adjust the [Noise level] on the [Details] Tab Page and try
teaching again.
If an edge is not detected when teaching, 0 will be registered as the reference width. If the result is OKed when
there is not edge, set the judgement parameters for a reference position of 0.
Edge Not Found
The measured edge width will be 0. Perform the following.
• If a color was specified, make sure the color of the measurement object has not changed from the specified
color.
• Set the color again if necessary.
• If there is an edge and it cannot be detected, make sure the [Edge level] parameter on the [Details] Tab Page
is correct.
Edge level: p. 122
Measured item
Range of value
Description
Judgement
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error
This is the measurement judgement results.
Edge Width (edge in
width)
−
99999.9999 to 99999.9999
This is the difference between the reference width and the measured
edge width.
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......