Inspecting with the Edge Position Inspection Item
122
FQ2 User’s Manual
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Edge Position]
−
[Details] Tab Page
−
[Output
parameter]
Changing Edge Detection Conditions (Sensors with Monochrome Cameras Only)
You can change the following measurement conditions for Sensors with Monochrome Cameras.
[Inspect]
−
[Inspection]
−
[Edge Position]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
Unstable Edge Position Results
There Is an Edge But It Cannot Be Detected
[Inspect]
−
[Inspection]
−
[Edge Position]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
−
[Edge Level]
Item
Parameter
Description
Density change
Light to Dark
Detects as an edge any position within the specified region that changes from
white to black.
Dark to Light
Detects as an edge any position within the specified region that changes from
black to white.
Measurement methods
Projection
A projection is formed based on the gray level, and any position of intersection
between the gray level value and the threshold (edge level) is detected as an
edge.
This detection method is used when you must process an image with exces-
sive noise or when the edges are blurry.
Differentiation
A differentiated waveform is created that represents the amount of change in
gray level between neighboring pixels. The maximum value of the differenti-
ated waveform that exceeds the threshold (edge level) is detected as an edge.
This detection method is used for low-contrast images.
Parameter
Setting
Description
Edge level
Range: 0 to 100
Default: 50
Set the color change level to detect as an edge.
The edge point is found based on a threshold that is set for a color change.
If you change the edge level, perform teaching again.
Edge Level
An edge is detected in the following way.
1. The color change distribution of the entire measurement region is determined.
2. The minimum color change is 0
%
. The maximum color change is 100
%
.
3. The location where the color change intersects with the edge level is detected as the edge.
Important
Note
100%
50%
0%
Minim
u
m color change
Edge le
v
el
Meas
u
rement
region
Maxim
u
m color change
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...