Inspecting with the Edge Position Inspection Item
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
167
Increasing Processing Speed for Edge Position
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 144
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or used
in calculations.
4-17 Calculations and Judgements Using Inspection Item Data: p. 197
Measurement Data That Can Be Logged for Edge Position
The following values can be logged as measurement data.
*
When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data: p. 252
Expression text string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error
X
Position X
This is the X coordinate of the mea-
sured edge position.
−
99999.9999 to 99999.9999
Y
Position Y
This is the Y coordinate of the mea-
sured edge position.
−
99999.9999 to 99999.9999
SX
Ref. position X (reference
position X)
This is the X coordinate of the edge
position when a range is set.
−
99999.9999 to 99999.9999
SY
Ref. position Y (reference
position Y)
This is the Y coordinate of the edge
position when a range is set.
−
99999.9999 to 99999.9999
DF
D. position (difference in
position)
This is the offset from the measured
reference position.
−
99999.9999 to 99999.9999
Measured item
Range of value
Description
Judgement
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the measurement judgement results.
D. position (difference in
position)
−
893 to 893
This is the offset from the measured reference position.
Position X
−
99999.9999 to 99999.9999
This is the X coordinate of the measured edge position.
Position Y
−
99999.9999 to 99999.9999
This is the Y coordinate of the measured edge position.
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......