[Output]
Signal: READY, BUSY, OR, and ERROR
Connect to the COMOUT terminal when using these signals.
Signal: STGOUT, SHTOUT
Connect to the COMIN and COMOUT terminals when using these signals.
Item
Specification
Output voltage
24 VDC±10%
45 mA max.
ON residual voltage
2 V max.
OFF leakage current
0.2 mA max.
*1.
Please use a load current at or below the specified value for current. Exceeding the specified current may
cause damage of the output circuit.
6 Power Supply and I/O Interface
6 - 11
FHV Series Smart Camera Setup Manual (Z408-E1)
6-4 I/O Cable Interface (Power Supply
, I/O, RS-232C)
6
6-4-4
Interface Specifications