Rating and Performance 

  (

F3SX-E-D1RR

F3SX-E-D1D1RR

Rating and Performance 

Item 

Model F3SX-E-D1RR 

Model F3SX-E-D1D1RR 

Rated power voltage 

24V DC

±

10% (ripple p-p 10% max) 

Rise time at turning power on 

5 seconds or less 

Protection for control circuit 

Protection from short-circuiting of output load, and protection from reverse connection of power supply. 
(Note 1 ) 

Over-voltage category (IEC60664-1) 

II 

Insulation resistance 

Collective lead wire from all terminals - external enclosure: 100M

Ω

  or more (by 500V DC megger) 

Withstand voltage 

Collective lead wire from all terminals - external enclosure: 2200V AC, 50/60Hz for 1 min.. 

Ambient temperature 

Operating: -10 to +50

  (not freezing or condensation)    Storage: -30 to +70

  (no freezing or condensation) 

Ambient humidity 

Operating and storage: 35 to 85%RH each (no freezing or condensation) 

Vibration resistance 

10 to 55Hz double amplitude of 0.7mm each in X, Y and Z direction, 20 sweeps (with power on) 

Shock resistance 

100m/s

2

 each in X, Y and Z direction, 1,000 times (with power on) 

Enclosure materials 

Glass fiber reinforced polyamide 66 (PA-66-FR) 

Protection structure 

Terminal block: IP20, Main body: IP40 (IEC60529) 

Emergency-stop input 
Reset input 
Feedback input 

Input 

Auxiliary input 

ON

F

 : 15 to 24V DC

±

10% 

OFF : Open or 0 to 5V DC 
Internal impedance: Approximately 5k

Ω

 

Safety output 

PNP transistor output 
Load current 300mA max (resistive load/inductive load) (Note 2) 
Residual voltage (for ON) : 2V max (Note 3) 
Residual voltage (for OFF) : 0.1V max 
Leakage current (for OFF) : 0.1mA max 
Permissible capacity load : 1 µF max 
Allowable wiring resistance between output terminal and load : 4

Ω

max 

DC solid-state 
output 

Auxiliary solid-state output 

PNP transistor output 
Load current : 25mA max , Residual voltage : 2V max (Note 3 ) 

Number of main contacts (safety outputs) 

DPST-NO 

Number of auxiliary contacts   

SPST-NC 

11/12 terminal 
(Auxiliary contact) 

250V AC 50/60Hz 30V DC 5A 

Resistive 
load 

23/24 terminal 
33/34 terminal 
(Main contacts) 

250V AC 50/60Hz 30V DC 3.15A (5A) (Note 4) 

Rated  
load 

Inductive load 

AC-15 : 240V AC / 2A cos 

φ

=0.3 

DC-13 : 24V DC / 1A L/R=48ms 

Minimum applicable load (Note 5) 

24V DC / 5mA (reference value) (Note 6) 

Electrical endurance (Note 5) 

100,000 times or more (open/close frequency of 1,800 times/h) 

Relay  
contact output 

Mechanical endurance (Note 5) 

10,000,000 times or more (open/close frequency of 36,000 times/h) 

Category, Performance level (PL) (EN ISO13849-1) 

Cat.4, PL e 

Cat.4, PL e 

Safety integrity level (IEC61508) 

SIL3 

SIL3 

Rated current 

500mA or less (except current consumption for the 
connected input/output devices) 

650mA or less (except current consumption for the 
connected input/output devices) 

DC solid-state safety output 
(SS1, SS2 terminal) 
Safety output monitor (AS1 terminal) 

ON

OFF : 30 ms or less 

OFF

ON : 126 ms or less 

ON

OFF : 35 ms or less 

OFF

ON : 147 ms or less 

Response 
time 

Safety relay output (23/24 terminal, 33/34 terminal) 
Auxiliary relay output (11/12 terminal) 

Response time : 40 ms or less 
Operating time : 156 ms or less 

Response time : 45 ms or less 
Operating time : 177 ms or less 

Weight 

Approximately 0.6kg (main body only) 

Approximately 0.7kg (main body only) 

External shape 

6 slots : 135(W)

×

111(H)

×

113(D) 

7 slots : 157.5(W)

×

111(H)

×

113(D)  

Connectable input devices 

Emergency-stop switch (common to Ch.1 and Ch.2)

 ・

Safety door switch (common to Ch.1 and Ch.2) 2sets 

Emergency-stop switch (common to Ch.1 and Ch.2)

 ・

Safety door switch (common to Ch.1 and Ch.2) 4sets 

(Note 1) When this protection function operates, recover by turning the main power ON again. 
(Note 2) Insert a surge absorber such as diode in parallel to the inductive load. 
(Note 3) Not including voltage drops in the extended wire. 
(Note 4) An external fuse must be inserted into the safety relay output. The fuse rating depends on the safety category. 

(1)  For the use of the Category 4, PL e (EN ISO13849-1) 
 

An external fuse must be inserted to protect the safety relay output contacts from welding. The fuse rating is 3.15A max. The current that can be applied to the safety 

relay contacts is limited by the fuse rating and it is 3.15A max (resistive load). 

(2)  Use under the Category 3, PL d (EN ISO13849-1) 
 

The external fuse rating is 5A or less than 5A. The current that can be applied to the safety relay contacts is limited by the fuse rating and it is 5A or less than 5A 

(resistive load). However, in this case, the safety relay output cannot be protected from welding.   

 

For the details, see the section 10.4.3.4 of prEN50156-1. 

(Note 5) Performance of the built-in relay itself. * The values for endurance are those at ambient temperatures b15 and +35°C and ambient humidities between 25 to 

 75%RH. 

(Note 6) Reference value. Use with less value is not appropriate. Note that, if loaded once with a higher value, the contacts may become unable to open/close for a small load.

 

 

 

„

LED Indicator

 

Indication Color 

Name 

Functions 

PW 

Green 

Power indicator 

Lights up while power is ON. 

ER Red 

Error 

indicator 

Lights up or flashes when an error occurs. 
Lighting up :No synchronization between emergency-stop inputs. 
1-time flashing :Short-circuiting or mis-wiring between emergency-stop inputs. 
2-time flashing :Trouble or mis-wiring around emergency-stop input circuit. 
3-time flashing :Mis-wiring or break around Y1, Y2 or Y3 terminal. 
4-time flashing :Trouble in DC solid-state safety output or around the circuit for DC   

solid-state safety output. 

5-time flashing : Trouble or welding around safety relay output circuit. 
6-time flashing :Error in feedback signals from an external devices. 
Continuously flashing :Affected by noises or trouble around the internal circuit of F3SX. 

RS 

Green 

Reset input indicator 

Lights up at the time of: 
Auto resetting:Y3 terminal input is ON. 
Manual resetting:Y2 terminal input is ON. 

LK 

Yellow 

Interlock indicator 

Lights up in interlock states. 

T1 

Green 

T12 input indicator 

Lights up when input is ON at T12 terminal. 

T2 

Green 

T22 input indicator 

Lights up when input is ON at T22 terminal. 

Green 

Safety output ON indicator 

Lights up when safety output is ON. 

Main Module

 

 

 

EN 

Red 

Safety output OFF indicator 

Lights up when safety output is OFF. 

 

D1 Module

 

 

 

„

LED Indicator

 

Indication Color 

Name 

Functions 

ER1 Red 

Error 

indicator 

Lights up or flashes when Terminal 5 or Terminal 7 input error occurs. 
Light-up  : Not synchronized between two terminal inputs 
1 flash 

: Short circuit or wrong wiring between two terminal inputs 

2 flashes  : Failure or wrong wiring of input circuit 

ER2 Red 

Error 

indicator 

Lights up or flashes when Terminal 12 or Terminal 10 input error occurs. 
Light-up  : Not synchronized between two terminal inputs 
1 flash 

: Short circuit or wrong wiring between two terminal inputs 

2 flashes  : Failure or wrong wiring of input circuit 

D1 

Green 

Terminal 5 input indicator 

Lights up for Terminal 5 input. 

D2 

Green 

Terminal 7 input indicator 

Lights up for Terminal 7 input. 

D3 

Green 

Terminal 12 input indicator 

Lights up for Terminal 12 input. 

D4 

Green 

Terminal 10 input indicator 

Lights up for Terminal 10 input. 

 

 

Relay output module (R Module) 

„

 LED Indicator 

Indication Color 

Name 

Functions 

EN1 

Green 

Safety relay output ON indicator 

Lights up when safety relay output is ON. 

EN1 

Red 

Safety relay output OFF indicator 

Lights up when safety relay output is OFF. 

 

 

 

 
 

„

 Example of wiring

 

  Note.F3SX-E-D1RR has two R modules.

 

F3SX-E-D1D1RR has two D1 modules and two R modules.

 

 

Main Module

E1

24V DC

A1

Y3

Y2

Y1

T22

T21

T11

T12

A2

FB

SS2

SS1

AS1

AS2

SSC

AS3

24V DC

24V DC

Control circuit

0V

S1

11

12

22

21

E1

24V DC

RY1

RY2

COM

24V DC

E1

KM1

KM2

AC

Fuses

RY1

RY2

KM2

KM1

S4

11

12

(NC contact)

S3

24

23

(NO contact)

Clo

se

Sa

fe

ty

 

Gua

rd

S6

11

12

(NC contact)

S5

24

23

(NO contact)

Clo

se

Sa

fe

ty

 

Gua

rd

D1 Module

9

12

11

10

24V DC

24V DC

Input 

circuit

Input 

circuit

8

5

6

7

24V DC

24V DC

Input 

circuit

Input 

circuit

Relay Output Module

12

34

24

33

11

23

K1

K2

KM4

KM3

Fuses

(R Module)

Relay Output Module

12

34

24

33

11

23

K3

K4

KM6

KM5

AC

Fuses

(R Module)

5

8

6

7

9

12

10

11

   Example with neither 
   safety limit switch nor 
   safety door switch 
   connected.

S1

Emergency-stop switch (positive opening contacts) (Model A165E, Model A22E)

S2

Reset switch

S3、S5

Limit switch

S4、S6

Safety limit switch (positive opening contacts) (Model D4N, Model D4B)

KM1〜KM6:Magnetic contact

or 

RY1、RY2:

Relay

M1〜M3

3 phase motor

E1

24V DC power source (Model S82K)

Note 1  :Example of wiring above corresponds to the Category 2.
Note 2  :Example of wiring above corresponds to the Stop Category (EN60204-1) 0.

KM3

KM4

KM5

KM6

S2

E1

24V DC

M

M3

M

M1

M

M2

 

 

Signal name 

Terminal 

name 

Operations 

Wiring when not used 

Safety output 
monitor 

AS1 

Outputs signal that is synchronous and in the same logics as those of the 
safety output. 

Open 

Ready output 

AS2 

When F3SX CPU has been initialized and the input and output have 
turned into normally controllable state, the output is turning ON. The 
output is OFF when the emergency-stop switch, connected to the main 
module, is pressed or the F3SX is lock-out. This output is also turning 
OFF unlike a Standby output when either of input apparatus turns OFF. 

Open 

Auxiliary 

solid-state 

output 

Standby output 

AS3 

When F3SX CPU has been initialized and the input and output have 
turned into normally controllable state, the output is turning ON. The 
output is OFF when the emergency-stop switch, connected to the main 
module, is pressed or the F3SX is lock-out. 

Open 

Feedback input 

FB 

In order to monitor the status of external devices, feeds back the input 
signal that is logically reversal to the DC solid-state safety output, such as 
the NC contact of the external contactor. Meanwhile monitoring whether 
the feedback input signal and DC solid-state safety output are 
synchronous, the device is brought in the lock-out state when they do not 
synchronize or the feedback signal is not input during the monitoring 
time. 

Main Module

A1

A2

FB

24V DC

Relay Outout

Module

12

11

(R Module)

When not connected, wire as shown in the figure below.

(Note 1)

 

Start command input 

SSC 

Inputs the start command received from the host side. Turns the safety 
output ON when the start command input and input signal of the 
connected device are both ON. 

Connect directly to the A1 terminal. 

  (Note 1) When the R1/R2 module is used, in consideration of a delay time setting value, it is necessary to change a threshold value of feedback monitoring time with the function 

set-up software for model F3SX (F3SX-CD

□□□

, sold separately).

 

 

„

 Error indications and measures to be taken 

When F3SX detects an error, indicator of ER lights up, or flashes to notify the error contents. Take appropriate measures according to the table below. 

„

Main module

 

ER indication 

Error 

Assumed causes 

Measures to be taken 

 

Lighting up 

Synchronization error of emergency-stop 
switch inputs. 

Defects in emergency-stop switch contacts. Or 
improper wiring with emergency-stop switch. 

Confirm emergency-stop switch or its wiring. 

 

1-time flashing 

Short-circuiting or wiring error among 
emergency- stop switch inputs. 

Short-circuiting around emergency- stop switch 
wiring. 

Confirm wiring with emergency-stop switch. 

Trouble with emergency-stop switch input 
circuit. 

Replace F3SX. 

 

2-time flashing 

Error around circuit of emergency-stop 
switch terminal. 

Affected by noises of excess level. 

Confirm noise environment surrounding F3SX. 

Improper wiring with reset input terminal. 

Confirm wiring with reset input terminal. 

Short-circuiting or wire break around reset input 
terminal. 

Confirm wiring with reset input terminal. 

 

3-time flashing 

Error around reset input terminal. 

Trouble with reset input terminal circuit. 

Replace F3SX. 

Trouble with the load (external device). 

Replace the load (external device). 

Improper wiring with the load (external device).

Confirm wiring with the load (external device). 

 

4-time flashing 

Error around DC solid-state safety output 
terminal. 

Trouble with DC solid-state safety output circuit.

Replace F3SX. 

Trouble with relay output. 

Replace F3SX. 

 

5-time flashing 

Error around relay output terminal. 

Affected by noises of excess level. 

Confirm noise environment surrounding F3SX. 

Improper wiring with external device such as 
contactor. 

Confirm wiring with external device such as contactor. 

 

6-time flashing 

Error around feedback input terminal. 

Trouble with external device such as contactor.

Replace the external device such as contactor. 

Affected by noises of excess level. 

Confirm noise environment surrounding F3SX. 

 

Continuously flashing

 

Disturbance by noises or trouble with 
F3SX. 

Trouble with F3SX internal circuit. 

Replace F3SX. 

 

  ■D1

module 

ER1 indication represents error occurring in the Ch.1, while ER2 indication represents error occurring in the Ch.2 side. 

ER1/ER2 
indication 

Error 

Assumed causes 

Measures to be taken 

 

Lighting up 

Synchronization error around inputs of 
input device. 

Defects in input device contacts. Or improper 
wiring with input device. 

Confirm input device or its wiring. 

 

1-time flashing 

Short-circuiting or wiring error among input 
device. 

Short-circuiting around input device. 

Confirm wiring with input device. 

Affected by noises of excess level. 

Confirm noise environment surrounding F3SX. 

 

2-time flashing 

Error around input terminal circuit of input 
device. 

Trouble with input circuit of input device. 

Replace F3SX. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 