27
F3SJ-B
User’s Manual
Ch
apt
e
r
3
Series
Con
nect
ion
Wiring/Installation
E
Connection Procedure
1.
Remove the caps from the primary sensor. Loosen the screw (M3 cross-shaped) to remove the cap.
2.
Use the F39-JBR2W series connection cable for extension to connect them.
3.
When changing the connection distance between the F3SJ-Bs, connect a F39-JD
B double-ended
connector cable (sold separately).
- When attaching a cable or cap, securely fasten the screws (M3 cross-shaped (2 for each), recommended torque:
0.54 N•m).
Failure to do so may cause the cable/cap to come loose, leading to deterioration of the protective functions.
- Attaching/detaching of a cap or a series-connection cable may cause misalignment of rubber grommet in a
connector assembly.
Press the grommet to the bottom of the connector and attach the connector F3SJ-B again.
1.
1.
1.
1.
2.
2.
2.
2.
3.
3.
3.
3.
Cap
Cap
F39-JBR2W
F39-JD
□
B
F39-JBR2W
F39-JD
□
B
Receiver’s
power supply
cable end
Emitter’s
power supply
cable end
Emitter’s
power supply
cable end
Receiver’s
power supply
cable end
<Secondary sensor>
<Primary sensor>
Содержание F3SJ-B Series
Страница 1: ...F3SJ B N25 01T Series Safety Light Curtain User s Manual Cat No SCHG 735E...
Страница 12: ...x Introduction F3SJ B User s Manual...
Страница 30: ...16 Chapter 2 Description of Functions F3SJ B User s Manual System Configuration and Functions...
Страница 84: ...70 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation...
Страница 90: ...76 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications...
Страница 96: ...82 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists...