79
F3SJ-B
User’s Manual
Ch
apt
e
r
5
Pre-
Op
erat
ion Chec
klis
ts
Checklists
E
Operation check while the machine is stopped
The test rod is not deformed.
Use a test rod with an appropriate diameter for inspection.
The sensor can detect a test rod wherever it is in the detection zone. In other words, when a test rod
is inserted into the detection zone, the stable-state indicators (STB) turn off and the ON/OFF output-
state indicators turn red.
When the external test function is used:
The ON/OFF-state indicator turns ON in red when the test input line is set to open or short-circuited
to 1/2 Vs to Vs.
Checking that hazardous parts stop while the machine operates
The hazardous parts stop immediately when a test rod is inserted into the detection zone at three
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SJ-B is turned OFF.
The actual response time of the whole machine is equal to or less than the calculated value.
Start
Stop
Содержание F3SJ-B Series
Страница 1: ...F3SJ B N25 01T Series Safety Light Curtain User s Manual Cat No SCHG 735E...
Страница 12: ...x Introduction F3SJ B User s Manual...
Страница 30: ...16 Chapter 2 Description of Functions F3SJ B User s Manual System Configuration and Functions...
Страница 84: ...70 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation...
Страница 90: ...76 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications...
Страница 96: ...82 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists...