8
Chapter
1
In
d
ica
to
r Di
sp
la
y
Pa
tt
ern
s
F3SJ-A
User’s Manual
Overview and Specifications
Indicator Display Patterns
No.
Indicators
Description
For basic system
For muting system
1
Incident light level indicator (LEVEL-
1 to 5)
Indication status of LEVEL-1 to 5 shows the incident light level status of the F3SJ. (*1)
2
Error mode indicator (ERROR-A to
C)
Turns ON or blink only on the sensor where the error occurred when the F3SJ enters
lockout. The error mode indicators remain OFF on sensors (emitters or receivers) where an
error did not occur, or on other series-connected sensors. The indication status of ERROR-
A to C shows the cause of the error (*2). Affix the error mode label (included) near the F3SJ
to allow for quick troubleshooting when errors occur.
3
Power indicator (POWER)
Turns ON while the power is ON.
4
Interlock indicator (INTLK) ON
Turns ON when F3SJ is in interlock state.
Not used
Blinking Blinks when in lockout.
5
External device
monitoring indicator
(EDM)
Muting input 1 indicator
(MUTE1)
ON
Turns ON when an input is given to external
device monitoring input.
Turns ON when an input is given to muting
input 1.
Blinking Not used
Not used
6
Test indicator (TEST)
Muting input 2 indicator
(MUTE2)
ON
Not used
Turns ON when an input is given to muting
input 2.
Blinking Blinks when external test is being
performed.
Not used
7
OFF-state indicator (OFF) ON
Turns ON when safety outputs are
OFF
.
Blinking Blinks when in lockout.
4. Interlock indicator (Yellow)
3. Power indicator (Green)
2. Error mode
indicator
1. Incident light level
indicator
EMITTER
LEVEL
POWER
ERROR
ERROR
INTLK
EDM
TEST
5
4
3
2
1
C
B
A
5
4
3
2
1
C
B
A
RECEIVER
LEVEL
OFF
ON
*1
LEVEL-5 (Green)
LEVEL-1 (Orange)
LEVEL-2 (Orange)
LEVEL-3 (Orange)
LEVEL-4 (Green)
ERROR-
C (Red)
ERROR-B (Red)
ERROR-A (Red)
LEVEL-1 (Orange)
LEVEL-2 (Orange)
LEVEL-3 (Orange)
LEVEL-4 (Green)
LEVEL-5 (Green)
ERROR-B (Red)
ERROR-A (Red)
ERROR-C (Red)
1. Incident light
level indicator
2. Error mode
indicator
8. ON-state indicator (Green)
7. OFF-state indicator (Red)
Emitter
Receiver
5. External device monitoring indicator (Green)
[Muting input 1 indicator]
6. Test indicator (Green)
[Muting input 2 indicator]
9. Not used (Green)
[Muting error indicator]
10. Not used (Green)
[Test indicator]
A set of square brackets, [ ], indicates name of an indicator under muting system.
*1 This label comes with a key cap for muting F39-CN6.
It must be attached to your sensor when the muting function is used.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]