97
F3SJ-A
User’s Manual
Chapter
4
Wiring Examp
le
s
Input/Output Circuit and Applications
E
Connecting to a G9SX-AD322-T15
•Can be configured for partial control and total control
•Can be extended to connect a door switch or a relay unit
A1
A2
S14 S24
KM1 KM2
S34 S44 S54
KM3 KM4
L1
X1 X2
T11
KM1
KM2
KM3
KM4
+24V
+24V
T12 T21 T22
T31 T32 T33 Y1
T41 T42
M1
M2
PLC, etc.
Motor controller
OFF
AND
KM1
KM2
KM3
S34
KM4
Control circuit
S1
S2
F39-JC A-L
F39-JC A-D
+DC24V
0V
E1
Feedback loop
- F3SJ settings
- Auto reset mode
- Not using external device monitoring
- G9SX-AD322-T15 settings
- Auto reset mode
- Using feedback loop
Emitter
Receiver
Motor controller
(operation command)
Model G9SX-AD322-T15
Open
Open
Open Open
Safety sensor safety output
KM1,KM2 N.C. contact
KM3,KM4 N.C. contact
KM1,KM2 N.O. contact
KM3,KM4 N.O. contact
Motor operation command
Motor rotation
OFF-delay time
Shield
0V (Blue)
(Red)
Open
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
Open
+24V (Brown)
Communication
line (+) (Grey)
Communication
line (-) (Pink)
+24V (Brown)
External devace monitoring input (Red)
Auxiliary output 1 (Yellow)
Safety output 1 (Green)
Safety output 2 (White)
0V (Blue)
Shield
S1
:External test switch
S2
: Lockout reset switch
KM1~KM4 :Magnetic contactor
M1, M2
: 3-phase motor
E1
:24VDC power supply (S82K)
PLC
:Programmable controller
(Used for monitoring -- not related to safety system)