43
F3SG-R
User’s Manual
Chapter
2
Auxiliary Output
System Operation and Functions
E
2-11. Auxiliary Output
Do not use the auxiliary output for safety applications.
Failure to do so may result in serious injury when the F3SG-RA fails.
2-11-1. Overview
The auxiliary output is used to monitor the status of F3SG-RA. This output can be connected to a
device such as an indication lamp, programmable controller, etc.
Usage Example:
• Indicate that F3SG-RA is in muting or override state
• Indicate that a machine is stopped (Safety outputs are in the OFF state)
The Auxiliary Output is not available for the F3SG-RE.
<Basic wiring diagram>
Sh
own below are hard wirings for PNP and NPN types, respectively.
The load current of the auxiliary output is 100 mA max.
F3SG-RA Series
X
F3SG-RE Series
Load
AUX: Red
Load
AUX: Red
0 V
0 VDC: Blue
0 VDC: Blue
F3SG-R
Receiver
PNP
F3SG-R
Receiver
NPN
+24 VDC: Brown
+24 VDC: Brown
+24 V
+24 V
0 V