Input/Output Circuit and Applications
5-2-1-3. Y-Joint Plug/Socket Connector using PNP outputs
The following is the example of Muting not used, External Device Monitoring enabled, Manual Reset
mode, PNP output and External Test in 24 V Active.
[DIP Switch settings] *3
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
[Wiring Example]
Function
DIP-SW1
DIP-SW2
Receiver
EDM Enabled
Manual Reset
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
㻞
㻻㻺
㻞
㻻㻺
㻟
㻻㻺
㻟
㻻㻺
㻠
㻻㻺
㻠
㻻㻺
㻣
㻻㻺
㻣
㻻㻺
㻠
㻻㻺
KM1
KM2
M
0 VDC: Blue
RESET:
Yellow *1
MUTE A: Gray
MUTE B: Pink
AUX: Red
OSSD1: Black
OSSD2: White
24 VDC: Brown
+24 VDC
0 VDC
Power supply
IN
PLC *2
KM1
KM2
F39-JG
B-L
F39-GCNY2
F39-JG
A-D
S1
KM1
KM2
S1: Lockout/Interlock Reset Switch
KM1,KM2: External device feedback
M: 3-phase motor
PLC: Programmable controller
(Used for monitoring only. NOT related to safety system.)
Unblocked
Blocked
Beam state
Reset Switch (S1)
OSSD
*1. Also used as EDM input line.
*2. When connecting to the PLC, the output mode must be
changed with the Configuration Tool according to your
application.
*3. The functions are configurable with DIP Switch. Refer to
Chapter 3 Setting with DIP Switch
for more information on
setting the functions by the DIP Switch.
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...