71
F3SG-4RA-25-02TS
User’s Manual
Chapter
4
Wiring
Wiring/Installation
E
4-5-3. Cable Connections
Extension of the cable must be within a specified length. If it isn't, safety function may not
work properly, resulting in danger.
Perform wiring according to the following procedure.
1.
Connect an emitter cable (F39-JD
□□□
-L, gray, sold separately) to the emitter-side power cable
(gray).
2.
Connect a receiver cable (F39-JJD
□□□
-D, black, sold separately) to the receiver-side power cable
(black).
4-5-3-1. Single-Ended Cable (Oil-Resistant Cable)
Single-Ended Cable for Emitter (F39-JD
□
RA-L, sold separately)
<Internal wiring diagram>
Single-Ended Cable for Receiver (F39-JD
□
RA-D, sold separately)
Fluororesin-insulated round cable dia. 6, 5-wire
(Cross section of conductor: 0.35 mm
2
(AWG22) / insulator diameter: dia. 1.13 mm)
M12 oil-resistant
connector
[Unit: mm]
40.7
L
Φ14.9
Connected to Power Cable or Double-Ended Cable
Brown
Black
Blue
+24 VDC
TEST
0 VDC
Not used
Not used
Not used
Not used
Not used
Female
5
8
4
3
2
1
7
6
㻙
㻙
㻙
2
7
5
6
1
8
3
4
Gray
Pink
Fluororesin-insulated round cable dia. 6, 8-wire
(Cross section of conductor: 0.35 mm
2
(AWG22) / insulator diameter: dia. 1.13 mm)
M12 oil-resistant
connector
[Unit: mm]
Φ14.9
L
40.7
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...