29
F3SG-4RA-25-02TS
User’s Manual
Ch
apt
e
r
3
Ro
ta
ry Switc
h
Setting with Rotary Switch and End Cap
E
3-2. Rotary Switch
Make sure to test the operation of the F3SG-R after setting with Rotary Switch to verify that the
F3SG-R operates as intended. Make sure to stop the machine until the test is complete.
Unintended settings may cause a person to go undetected, resulting in serious injury or death.
F3SG-R series has the Rotary Switches to configure functions near the power cable. Configure functions with
the Rotary Switches before installing F3SG-R in your site. Make sure to turn the power of the F3SG-R on after
the setting with the Rotary Switches is complete.
Cascaded sensors are operated based on the Rotary Switches setting of the primary sensor. The Rotary
Switch setting of a secondary sensor does not affect the operation.
For F3SG-R series, the following functional settings are available by the Rotary Switch on the emitter and
receiver.
- Operate the Rotary Switches before turning the power of the F3SG-R on.
- Both the emitter and receiver units must be set to the same code.
- A change of the Rotary Switches setting is activated upon power-on or lockout reset.
- If the Rotary Switch is operated during operation of the F3SG-R, the F3SG-R transitions to lockout.
Function
Position
Description
Refer to
Scan Code Selection
Code A
(factory default setting)
Code B
Rotary Switch
Rotary Switch
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...